AM.PM spirit f7002100, для умывальника [3/20] F7002100 f7082100

AM.PM spirit f7007000, для кухни [3/20] F7002100 f7082100
4 5
F7002100/F7082100
F7083100
Operating interval of pressure in water supply network 0,5 – 6,0 Atm.(50-620kPa).
Recommended pressure interval in water supply network 2,0 – 5,0 Atm (206 – 515 kPa).
Difference of cold and hot water pressure should not exceed +/- 10%. In case of deviation of
water supply system pressure parameters to the specied values installation of devices for
pressure increase/reduction is required.
To avoid mechanical (abrasive) particles penetration inside the product it is compulsorily required
to install lters of 100-300 mk.
mIxeR InSTallaTIon.
1.Disconnect hot and cold water supply system
2.Remove (screw loose) aerator (to avoid aerator clogging during rst water startup).
3.Fix mixer at the sanitary ware using tting included into the delivery set.
4. Connect mixer to the water supply system). Switch on water supply system. Check
leakproofness of all connections during mixer closed position. When necessary arrange additional
tightening and sealing of connections (when closing valves of supply pipelines are closed).
5. Open cold and hot water supply for short period of time (for washing of pipes), then close the
water supply and install (screw tight) the aerator.