Operating pressure range in the water mains is 1.5 – 6.0 atm (120-600kPa). Pressure difference for hot and cold
water can vary + / - 10%. If pressure parameters in the water mains differ from the speci ed value, input pressure
increase or input pressure relief device is required.
To avoid ingress of solids (abrasive particles) in the mixing valve, it is recommended to apply 100-300 micron lters.
1. Close off hot and cold water supply. Screw in the at-end reducers. Screw in the eccentric adapters in water
supply piping outlets with pre-sealing of the threaded part with insulating material. Adjust the position of eccentric
reducers so that they match and meet the connecting position of the mixing valve, and the mixing valve is horizontal
(distance between the eccentrics – 150mm OC).
2. Remove (unscrew) the aerator (to avoid clogging the aerator at the rst start-up of water).
3. Fasten the trim to the eccentric reducers, using tool with soft parts (to avoid damage to the decorative coating of
mixing valve nuts), mount the valve housing.
4. Turn on the water supply. In the closed position
of the valve, check sealing of all the connections. If
necessary, make extra tightening and sealing of the
connections (be sure to close off the water supply).
5. Attach the shower hose and the shower head.
6. Start the cold and hot water running for a short
period of time, then close the water supply and
install (tighten) the aerator.