Operating pressure range in the water mains is 1.5 – 6.0 atm (120-600kPa). Pressure difference for hot and cold
water can vary + / - 10%. The recommended pressure is 2.5 atm. If pressure parameters in the water mains differ
from the speci ed value, input pressure increase or input pressure relief device is required.
To avoid ingress of solids (abrasive particles) in the mixing valve, it is recommended to apply 100-300 micron lters.
1. Close off hot and cold water supply.
2. Remove (unscrew) the aerator (to avoid clogging the aerator at the rst start-up of water).
3. Connect the exible hoses to the valve. The exible hoses should be screwed into the valve slot only by hand
without using tools or applying excessive force, because this can cause damage the hoses or the valve.
4. Fasten the mixing valve on the sanitary ware, using the supplied fasteners.
5. Connect the valve to the water supply system, using the connecting ttings (upset couplings). Turn on the water
supply. In the closed position of the valve, check sealing of all the connections. If necessary, make extra tightening
and sealing of the connections (be sure to close the shut-off valves on water supply piping).
6. Start the cold and hot water running for a short period of time (to wash off the pipes), then close the water supply
and install (tighten) the aerator.