5
B
ASIC CONNECTORS
serial com
The serial connector is to be used for interfacing with APC PowerChute
software and terminal emulation software.
Use only cables approved by APC.
Any other interface cable will be incompatible with the UPS
connector.
normal bypass
Manual bypass enables the user to manually put connected equipment into
bypass mode.
EPO terminal
Emergency Power Off terminal allows the user to connect the UPS to the
central EPO system.
TVSS screw
The UPS features a transient voltage surge-suppression (TVSS) screw for
connecting the ground lead on surge suppression devices such as telephone
and network line protectors.
When connecting grounding cable, disconnect the unit from the utility
power outlet.
external battery
pack connector
Optional external battery packs provide extended run time during power
outages. These units support up to ten external battery packs.
See the APC Web site, www.apc.com
for the information on the external
battery pack, SURT192XLBP.
5000 VA
XLI models
output circuit
breakers
3000/5000VA
XLJ/XLT/
XLTW
models
output circuit
breakers
Содержание
47- Installation and operation
- Smart ups rt
- English
- Surtd 3000 5000 va 200 240 vac
- Smart up
- Tower rack mount 3u
- Uninterruptible power supply
- Serial cable
- Nstallation
- Software cd
- Product documentation
- Xlt xli
- Conversion faceplate for accommodating a network management card
- By schneider electric smart up
- Specifications
- Models powerchut
- Literature kit containing
- Warranty information
- Introduction
- Ups with battery modules disconnected
- Inspect the ups upon receipt notify the carrier and dealer if there is damage
- Unpacking
- Front bezel
- Two output power cords two input power cords
- Four output power cords network management card documentation
- The packaging is recyclable save it for reuse or dispose of it properly
- Check the package contents
- The ap
- Smart ups rt user manuals cd
- Rt is a high performance uninterruptible power supply ups that provides protection for electronic equipment from utility power blackouts brownouts sags and surges the ups filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power the ups provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged
- Read the safety guide before installing the ups
- Wiring and connecting the ups
- Peration
- Onfigurable
- Replacing the battery module
- Ransport
- Aintenance and
- Disconnecting the battery for transport
- Roubleshootin
- Use the table below to solve minor installation and operation problems refer to the apc web site www apc com for assistance with complex ups problems
- Nformation
- Arranty
- Service
- Limited warranty
- Apc worldwide customer support
- Requency
- Arnings
Похожие устройства
-
APC Back-UPS Pro BR1600SIРуководство по настройке -
APC Back-UPS Pro BR1200SIЭксплуатационная инструкция -
APC BX1400UIИнструкция по применению -
APC BX950UIРуководство по эксплуатации -
APC SRV3KIL-BRРуководство по настройке -
APC SRV3KIL-ARИнструкция по применению -
APC SRV3KILРуководство по настройке -
APC SRV2KIL-BRРуководство пользователя -
APC SRV2KIL-ARРуководство по эксплуатации -
APC SRV2KILИнструкция по применению -
APC SRV1KIL-BRИнструкция по работе -
APC SRV1KIL-ARЭксплуатационная инструкция
Узнайте о различных разъемах для подключения оборудования к источникам бесперебойного питания. Информация о ручном обходе, терминале EPO и внешних батареях.