APC Smart-UPS SURTD5000XLI — описание индикаторов и функций источника бесперебойного питания [9/22]
Превью страниц
Страница 9 /
22
![APC Smart-UPS SURTD5000XLI [9/22] Peration](/views2/1159313/page9/bg9.png)
7
OPERATION
Load
SMART-UPS RT FRONT DISPLAY
Battery Charge
Indicator Description
Online
The Online LED illuminates when the UPS is drawing utility power and performing
double conversion to supply power to connected equipment.
On Battery
The UPS is supplying battery power to the connected equi
p
ment.
Bypass
The Bypass LED illuminates indicating that the UPS is in bypass mode. Utility
power is sent directly to connected equipment during bypass mode operation.
Bypass mode operation is the result of an internal UPS fault, an overload condition
or a user initiated command either through an accessory or the manual bypass
switch. Battery operation is not available while the UPS is in bypass mode. Refer to
Troubleshooting in this manual.
Fault
The UPS detects an internal fault.
Refer to Troubleshooting in this manual.
Overload
An overload condition exists. See Troubleshooting.
Replace
Battery
The battery is disconnected or must be replaced. See Troubleshooting.
Feature Function
Power On
Press this button to turn on the UPS. (See below for additional capabilities.)
Power Off
Press this button to turn off the UPS.
Содержание
47- Installation and operation
- Smart ups rt
- English
- Surtd 3000 5000 va 200 240 vac
- Smart up
- Tower rack mount 3u
- Uninterruptible power supply
- Serial cable
- Nstallation
- Software cd
- Product documentation
- Xlt xli
- Conversion faceplate for accommodating a network management card
- By schneider electric smart up
- Specifications
- Models powerchut
- Literature kit containing
- Warranty information
- Introduction
- Ups with battery modules disconnected
- Inspect the ups upon receipt notify the carrier and dealer if there is damage
- Unpacking
- Front bezel
- Two output power cords two input power cords
- Four output power cords network management card documentation
- The packaging is recyclable save it for reuse or dispose of it properly
- Check the package contents
- The ap
- Smart ups rt user manuals cd
- Rt is a high performance uninterruptible power supply ups that provides protection for electronic equipment from utility power blackouts brownouts sags and surges the ups filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power the ups provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged
- Read the safety guide before installing the ups
- Wiring and connecting the ups
- Peration
- Onfigurable
- Replacing the battery module
- Ransport
- Aintenance and
- Disconnecting the battery for transport
- Roubleshootin
- Use the table below to solve minor installation and operation problems refer to the apc web site www apc com for assistance with complex ups problems
- Nformation
- Arranty
- Service
- Limited warranty
- Apc worldwide customer support
- Requency
- Arnings
Похожие устройства
-
APC Back-UPS Pro BR1600SIРуководство по настройке -
APC Back-UPS Pro BR1200SIЭксплуатационная инструкция -
APC BX1400UIИнструкция по применению -
APC BX950UIРуководство по эксплуатации -
APC SRV3KIL-BRРуководство по настройке -
APC SRV3KIL-ARИнструкция по применению -
APC SRV3KILРуководство по настройке -
APC SRV2KIL-BRРуководство пользователя -
APC SRV2KIL-ARРуководство по эксплуатации -
APC SRV2KILИнструкция по применению -
APC SRV1KIL-BRИнструкция по работе -
APC SRV1KIL-ARЭксплуатационная инструкция
Узнайте о различных индикаторах и функциях источника бесперебойного питания, включая режимы работы, диагностику и управление. Подробности внутри.