1 1 2 3 4 Flame failure device model dependant Spark plug Injector Burner B nless there Is an abnormal condition do ot attempt to remove the gas burner taps ou must call an Authorised service agent if is necessary to change the taps Reduced gas flow rate setting for hob taps 1 Ignite the burner that is to be adjusted and turn the knob to the reduced position 2 Remove the knob from the gas tap 3 Use an appropriately sized screwdriver to adjust the flow rate adjustment screw For LPG Butane Propane turn the screw clockwise For the natural gas you should turn the screw counter clockwlseonce The normal length of a straight flame in the reduced position should be 6 7 mm 4 If the flame is higher than the desired position turn the screw clockwise If it is smaller turn anticlockwise 5 For the last control bring the burner both to high flame and reduced positions and check whether the flame is on or off Depending on the type of gas tap used in your appliance the adjustment screw position may vary 1 Flow rate adjustment screw Exchange of injector for the oven 1 Unscrew fastening screws of the back wall 2 Unscrew the 2 screws 2 of the injector holder 1 14 EN