Netis ST3105GM [4/8] Troubleshooting

Содержание

metis Unmanaged Switch Quick Installation Guide 2 Troubleshooting 1 The Power PWR LED is not on Check if the Power Adapter Power Cord is well connected Try to unplug and plug back in the Power Adapter Power Cord to the switch or try another power outlet 2 The LINK ACT LED is not on Make sure the network configuration of connecting device is correct and network card and drivers are installed correctly Check the cable connections Make sure the cable distance between the switch and other IEEE802 3 compatible network device does not exceed 100 meters 3 Performance is bad Check the status of Ethernet switching If Ethernet switching is set to full duplex on one device but a partner is set to half duplex then performance will be poor Make sure the cable between the switch and other IEEE802 3 compatible network device is Category 5 UTP or better 4 Some devices can t talk to other devices on the network Check status of the LINK ACT LEDs to make sure devices are linked Make sure that the devices network configurations are correct Reset the switch if needed Technical Support support netis systems com NETIS SYSTEMS CO LTD www netis systems com MADE IN CHINA 3