D-Link dgs-1510-28 [454/702] Example

D-Link dgs-1510-28 [454/702] Example
DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
451
[2] - PD Short.
[3] - Overload.
[4] - Power Denied.
[5] - Thermal Shutdown.
[6] - Startup Failure.
[7] - Classification Failure(IEEE 802.3at).
Class
The IEEE classification: N/A or a value from IEEE class 0 to 4.
Max(W)
The maximum amount of power could be allocated to the powered
device in watts.
Used(W)
The amount of power is currently allocated to PoE ports in watts.
Description
The configured description of the connected PD.
Example
This example shows how to display the PoE power inline configuration.
Switch# show poe power-inline configuration
Interface Admin Priority Legacy-Support Time-Range
--------------------------------------------------------------------------------
eth3/0/1 auto critical enabled 12345678901234567890123456789012
eth3/0/2 auto(M) critical disabled rdtime
!--- Output suppressed...
eth4/0/2 auto critical disabled
eth4/0/3 never high disabled
!--- Output suppressed...
eth5/0/24 never low disabled
eth5/0/25 never low disabled
Switch#
Display Parameters
Interface
The PoE interface ID.
Admin
The user configured mode can be of the following:
Auto - The powered device will be automatically detected and
maximum power is based on the detection result.
Auto(M) - The powered device will be automatically detected and
maximum power is the user configured value.
Never - The powered device will not be detected, and no power to the
port.
Priority
The priority used to prioritize the service order when power constrain
happens within at the power unit.
Legacy-Support Enabled - The legacy PD can be detected.
Disabled - The legacy PD cannot be detected.
Time-Range
The time-range profile name which sets the activation time frame for a
port.
Example
This example shows how to display the PoE power inline statistics.