Osram htm 150вт, 230-240в Инструкция по эксплуатации онлайн

Electronic transformers for 12 V
halogen lamps
• Optimum lamp life
• Compact for small spaces
• Reversible switch off in case of short-
circuits, overload and overtemperature
• Dimming on the primary side is
possible. A corresponding dimmer
has to be used (suitable dimmers see
table)
Connecting the transformers to the
lamps
• Ensure that the lamp load is within the
output range of the transformers (see
table)
• Transformers can be connected in
parallel on the primary side (fig. 1a)
• Do not connect the transformers in
parallel or series on the secondary
side (fig. 1b)
• The maximum load of the transformer
can be connected to any of the lamp-
side terminal pairs (except HTL 225)
Wiring
• In accordance with the EN 60598
standard, the recommended
connecting cables (see table) must be
held firmly by the cable clamp to
prevent it from being pushed or pulled
• Secondary side: cable length maximum
2 m, minimum 0.3 m (fig. 2 and 3)
• To prevent radio interference keep lamp
cables as short as possible, keep them
away from metal surfaces and keep
them separated as far as possible from
mains cables (fig. 2 and 3: angles ≥ 90°).
Do not route cables along the
transformers
• When using single leads of a cable,
secondary wires have to be twisted
in pairs
• For units installed in fixtures the
luminaire manufacturer is responsible
for RFI-compliance
Temperatures
• Avoid high temperatures. Do not place
the transformers close to the lamp
(minimum distance 0.3 m). Maximum
permissible ambient temperature must
not be exceeded (see table). Make sure
there is adequate space to avoid a
build-up of heat. In critical installations
the temperature at t
c
has to be
controlled
Caution
•
Transformers must be installed by a
qualified electrician
• Electronic transformers are not suitable
for any other load than low voltage
halogen lamps
• No switching or dimming on secondary
side
HALOTRONIC
®
1. a
2.
1. b
3.
correct incorrect
35 W
35 W
35 W
100 W
HALOTRONIC
105 W
HALOTRONIC
105 W
HALOTRONIC
105 W
35 W
4. Wire stripping (see table)
Prim. Sec.
Optimum
area for
primary cable
Optimum
area for
secondary
cables
230 – 240 V
50 – 60 Hz
max. 2 m
min. 0.3 m
HTM 70
HTM 105
HTN 75
90° 90°
Optimum
area for
primary cables
Optimum
area for
secondary
cables
Prim. Sec.
HTL 105
HTL 225
HTM 150
max. 2 m
min. 0.3 m
90°
mains
next
unit
not used
A
B
10 W
120 W
HALOTRONIC
105 W
HALOTRONIC
105 W
HALOTRONIC
105 W
HALOTRONIC
105 W
Содержание
Похожие устройства
- Osram htm 70вт, 230-240в Инструкция по эксплуатации
- Osram htm 105вт, 230-240в Инструкция по эксплуатации
- Oursson mf2500/or Инструкция по эксплуатации
- Oursson ek1555m/dc, 1.5 л Инструкция по эксплуатации
- Pharaon lc-100 Инструкция по эксплуатации
- Pharaon lc-40 Инструкция по эксплуатации
- Pharaon x180 Инструкция по эксплуатации
- Orient hvr-9104ahd Инструкция по эксплуатации
- Orient dp-950-p6b Инструкция по эксплуатации
- Orient yc-11-p8c Инструкция по эксплуатации
- Orient yc-11-y7c Инструкция по эксплуатации
- Orient dp-960-s12b Инструкция по эксплуатации
- Orient yc-11-p6c Инструкция по эксплуатации
- Orient yc-140-s12d Инструкция по эксплуатации
- Panasonic lumix dmc-lz40, black Инструкция по эксплуатации
- Panasonic lumix dmc-sz8 black Инструкция по эксплуатации
- Panasonic hc-v730 black Инструкция по эксплуатации
- Panasonic hc-w850 black Инструкция по эксплуатации
- Panasonic hc-v750 black Инструкция по эксплуатации
- Panasonic kx-dt333ru Инструкция по эксплуатации