Timberk TEF F16 FM2 [4/5] Assembly

ENGLISH SAFEGUARDS Dear customer 1 Before the first use read all the instructions and study the respective figures Use theapplianceonly in accordance with the user s manual 2 Before connection of the appliance to power network please check if the voltage indicated on the appliance corresponds to the voltage in the point ofconnection 3 Never connect the appliance if its assembling is not completed 4 Never operate the appliance with cracks and other damages of propeller 5 For reasons of your own safety and safety of other people please remember that entry of water in the electric appliance is dangerous Do not use the appliance in close proximity to a bathtub shower or swimming pool 6 Do not use the appliance if the power cord is damaged or if there are any other possible internal damages faults in operation 7 Use of electrical contacts not approved for use or different from those supplied with the appliance may cause faults in operation or a short circuit 8 Do not touch the power cord and make sure that it is not pressed with bits of furniture etc 9 Unplug the appliance if it is necessary to move it or when it is not intended to use itfor a long time We thank you for your happy choice You ve bought an electric fan Timberk It will serve you for a long time Electric fan Timberk is designed for creation of comfortable coolness The fan may be installed upright on a rigid base in places where it is possible to connect it to electric wiring single phase electric supply 220 230 V 50 Hz is required PLEASE READ THIS MANUAL CAREFULLY BEFORE MOUNTING AND OPERATIING OF THE FAN FAN USER S MANUAL Important safeguards and instructions contained in this manual do not include all possible modes and situations which may occur It is necessary to understand that common sense caution and accuracy are the factors which cannot be built in any product These factors should be considered by a person who is interested in the proper operation of the appliance The manufacturer is nor responsible for damage of the appliance during transportation as a result of incorrect installation as a Q ATTENTION result of voltage fluctuations as well as when any part of the appliance has been changed or modified SPECIFICATIONS J Model TEFF16FM2 Maximum powert W 40 Maximum height mm 1250 Net weight kg Gross weight kg 1 26 1 3 14 For more detailed description of technical parameters and specifications visit www timberk ru or ask official dealers of TIMBERK HHA Company 6 www tlmberk ru floor type electric fan Do not operate the appliance near explosive or inflammable substances The appliance should never be located bear open fire stoves and other heating appliances Never immerse components of the appliance in water or other liquid Do not operate the appliance outdoors 10 Always be very careful when the appliance is used by children by children or nearthem 11 Always puttheapplianceonly on flat dry surface 12 Donotoperatetheappliancewithoutgrilles 13 Do not touch the grilles with a view to turn the appliance or to stop its operation 14 Never insert any objects in grilles if the appliance is connected to a power source 15 It is not recommended for people especially children and seniors to be under continuous exposure to cold airflow 16 Do not operate the appliance outdoors 17 This appliance is designed only for residential use and should not be used in industrial conditions ATTENTION The manufacturer alterations not reserves deteriorating the the fan right to quality introduce and reliability structural without any special notification GENERAL DESCRIPTION ASSEMBLY 1 Release and remove four screws A from a support 2 Cross two supports and insert support legs in them Match four apertures on the supports with apertures in a rack 3 Screw the rack to the support with the use of four screws A They should be screwed in strict successive order 4 Put a support strap on screws to cover them 5 Pull out an internal tube from the rack and fix it with the use of a height adjustment screw 6 Attach the fan body to the internal tube by fixing it with screw B Fig 1 1 Back grille 2 A button for change of air flow horizontal direction 3 Electric motor 4 Screw C 5 Fan body 6 Screw B 7 Power cord 8 Internal tube 9 Height adjustment screw 10 Rack 11 Support strap 12 Support 13 Screw A 14 Support legs 15 Control buttons 16 Back grille screw 17 Propeller 18 Propeller screw 19 Front grille 20 Front grille escutcheon ATTENTION If mechanical or electrical repair of the appliance is needed always apply to authorized service centers of TIMBERK The list of service centers you may find at www timberk ru or ask from a shop assistant 7 Mount the back grille on the front of the electric motor by matching three mounting apertures on the back grille with three mounting dowels on the front of the electric motor 8 Attach the back grille to the electric motor with the use of the back grille locknut 9 Fix the propeller on the motor shaft Make sure that the shaft pin enters the aperture on the propeller 10 Fix the propeller with the use of the propeller screw by tightening it counterclockwise 11 Check the propeller work by revolving it At that there should not be any friction of the back grille screw If the propeller does not revolve freely dismantle the structure and repeat the procedure clauses 7 11 12 Connect the front grille with the back one and attach them to each other depending on the model screws may be tightened from below or from above www timberk fu floor type electric fan

Скачать