Supermicro cse-836be16-r920 — руководство по управлению перегревом шасси и индикаторами [36/146]

Supermicro cse-836be16-r920 [36/146] Confirm that the chassis covers are installed properly
SC836 Chassis Manual
3-4
Overheating
There are several possible responses if the system overheats.
Overheat Temperature Setting
Some backplanes allow the overheat temperature to be set at 45, 50, or 55 by
changing a jumper setting. For more information, consult the backplane user manual
at www.supermicro.com. (Click Support, then the Manuals link.)
Responses
If the server overheats:
1. Use the LEDs to determine the nature of the overheating condition.
2. Conrm that the chassis covers are installed properly.
3. Check the routing of the cables and make sure all fans are present and operating
normally.
4. Verify that the heatsinks are installed properly.
3-4 Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA drives. Each drive carrier
displays two status LEDs on the front of the carrier.
LED Color Blinking Pattern Behavior for Device
Activity LED
Blue Solid On SAS drive installed
Blue Blinking I/O activity
Status LED
Red Solid On Failed drive for SAS/SATA/NVMe
with RSTe support
Red Blinking at 1 Hz Rebuild drive for SAS/SATA with
RSTe support
Red Blinking with two
blinks and one stop
at 1 Hz
Hot spare for SAS/SATA with
RSTe support
Red On for ve
seconds, then off
Power on for SAS/SATA with
RSTe support
Red Blinking at 4 Hz Identify drive for SAS/SATA with
RSTe support