C-8
SC835 Chassis Manual
Jumper Settings
Jumper Jumper Settings Note
JP35
1-2: Reset
2-3: No reset
MG9072 chip reset
Socket Settings
Socket Socket Setting Note
JP18 Connected to front panel
Buzzer reset*
Press once to disable buzzer
Press twice to enable buzzer
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following conditions:
1. Hard drive failure
2. Fan failure
3. System temperature over 45º Celsius.
Fan Jumper Settings
This backplane can use up to three fans. To utilize each fan, you must congure
both jumpers as instructed below.
Fan Jumper Settings
Jumper Jumper Settings Note
JP61
1-2: With fan
2-3: No fan
FAN #1 select
JP97
1-2: With fan
2-3: No fan
FAN #1 select
JP62
1-2: With fan
2-3: No fan
FAN #2 select
JP98
1-2: With fan
2-3: No fan
FAN #2 select
JP63
1-2: With fan
2-3: No fan
FAN #3 select
JP99
1-2: With fan
2-3: No fan
FAN #3 select