Graco Pro-Shot 24H406 [2/2] Adjustment

Graco Pro-Shot 24H405 [2/2] Adjustment
2 309119
Installation
See instruction manual 309032 for troubleshooting guide. Replace all parts included in this service kit, checking all
parts thoroughly when disassembling, and carefully replace any additional parts that are worn or damaged.
Adjustment
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure in instruction manual
309032.
1. Relieve the pressure.
2. To adjust the clearance, loosen the top nut (Fig. 1,
item 5) and turn the bottom nut (5) in or out as
needed. Hold the bottom nut in place and securely
tighten the top nut.
3. For less than maximum flow, back off bottom
nut (5).
Fig. 1
5
1
1
Turn adjusting nut (5) down until yoke bottoms out
on rod guide or until resistance is noticeably greater
(max flow setting)
Torque 80 100 ft. lbs.
TI0628
Yoke
Rod Guide
All information, illustrations and specifications in this document are based on the latest product information available at the time
of publication. The right is reserved to make changes at any time without notice.
Sales Offices: Minneapolis, Detroit
International Offices: Belgium, Korea, Hong Kong, Japan
www.graco.com
PRINTED IN U.S.A. 309119 01/2000, Revised 02/2002