Moxa PT-7528-12MST-12TX-4GSFP-WV [2/8] Specifications

Moxa PT-7528-20MSC-4TX-4GSFP-HV-HV [2/8] Specifications
Industry-specific Ethernet Switches
2
www.moxa.com
Specifications
Technology
Standards:
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Software Features
Management: IPv4/IPv6, SNMPv1/v2c/v3, DHCP Server/ Client,
BootP, TFTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, DHCP
Option 66/67/82, LLDP, Flow Control, Back Pressure, SNMP Inform,
Port Mirror, Fiber Check, Syslog
Filter: IGMPv1/v2, GMRP, GVRP, 802.1Q VLAN, VLAN Unaware,
Port-Based VLAN, GVRP
Redundancy Protocols: STP/RSTP, MSTP, Turbo Ring v1/v2, Turbo
Chain, Link Aggregation
Security: RADIUS, TACACS+, SSL, SSH, Port Lock, Broadcast Storm
Protection, Rate Limit
Time Management: SNTP, NTP Server/Client, IEEE 1588v2 PTP
(software-based)
Industrial Protocols: EtherNet/IP, Modbus/TCP
MIB: MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge
MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Power Substation: MMS, IEC 61850 QoS, Configuration Wizard
Switch Properties
Priority Queues: 4
Max. Number of VLANs: 256
VLAN ID Range: VID 1 to 4094
IGMP Groups: 256
Jumbo Frame Size: 9728 bytes
Interface
RJ45 Ports: 10/100/1000BaseT(X) auto negotiation speed
Fiber Ports: 100/1000BaseSFP slot, 100BaseFX Multi-mode ST/SC
Connector
Console Port: USB console port (Type B connector)
Storage Port: USB storage port (Type A connector)
Alarm Contact: 1 relay output with current carrying capacity of 3 A @
30 VDC or 3 A @ 240 VAC
Optical Fiber
100BaseFX
Multi-mode Single-mode
Single-mode,
80 km
Wavelength
1300 nm 1310 nm 1550 nm
Max. TX
-10 dBm 0 dBm 0 dBm
Min. TX
-20 dBm -5 dBm -5 dBm
RX Sensitivity
-32 dBm -34 dBm 34 dBm
Link Budget
12 dB 29 dB 29 dB
Typical Distance
5 km
a
4 km
b
40 km
c
80 km
d
Saturation
-6 dBm -3 dBm -3 dBm
a. 50/125 μm, 800 MHz*km fiber optic cable
b. 62.5/125 μm, 500 MHz*km fiber optic cable
c. 9/125 μm single-mode fiber optic cable
d. 9/125 μm single-mode fiber optic cable (80 km)
Power Requirements
Input Voltage:
•WV:24/48VDC
•HV:110/220VDC/VAC
Operating Voltage:
•WV:18to72V
•HV:88to300VDCand85to264VAC
Input Current: For models with fewer than 8 fiber ports:
•Max.0.741A@24VDC
•Max.0.364A@48VDC
•Max.0.147/0.077A@110/220VDC
•Max.0.283/0.19A@110/220VAC
For models with 8 or more fiber ports:
•Max.1.428A@24VDC
•Max.0.735A@48VDC
•Max.0.313/0.167A@110/220VDC
•Max.0.586/0.382A@110/220VAC
Overload Current Protection: Present
Connection: 10-pin terminal block
Reverse Polarity Protection: Present
Physical Characteristics
Housing: Aluminum alloy
IP Rating: IP40 protection
Dimensions: 440 x 44 x 325 mm (17.32 x 1.73 x 12.80 in)
Weight: 4900 g (10.89 lb)
Installation: 19-inch rack mounting
Environmental Limits
Operating Temperature: -40 to 85°C (-40 to 185°F), cold start
requires min. of 100 VAC at -40°C
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
Safety: UL 508
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
IEC 61000-4-11
Rail Traffic: EN 50121-4
Transportation: NEMA TS2
Electrical Substation: IE C61850-3, IEEE 1613 Class 2 (models with
MCS and SSC fiber ports are compliant with IEEE 1613 Class 1)
MTBF (mean time between failures)
Time: 422,912 hrs
Standard: Telcordia TR/SR
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty