Alarm Contact
The IMC-101G has one alarm contact located on the top panel. For
detailed instructions on how to connect the alarm contact power wires to
the two middle contacts of the 6-contact terminal block connector, see
the “Wiring the Alarm Contact” section above. A typical scenario would be
to connect the fault circuit to a warning light located in the control room.
The light can be configured to switch on when a fault is detected.
The alarm contact has two terminals that form a fault circuit for
connecting to an alarm system. The two wires attached to the fault
contacts form an open circuit when (1) the IMC-101G has lost power from
one of the DC power inputs, or (2) one of the TP/SFP ports for which the
corresponding PORT ALARM DIP Switch is set to ON is not properly
connected. If neither of these two conditions occurs, the fault circuit will
be closed.
IMC-101G DIP Switch Setting
NOTE
To activate updated DIP switch settings, power off and then
power on the IMC-101G.
Dip Switch 1
(Default: Off)
On:
Enables the PORT ALARM. If the product
experiences a power failure, or the Ethernet port
link fails,
the relay will form an open circuit and the
fault LED will light up.
Off:
Disables the corresponding PORT ALARM. The relay
will form a closed circuit and the
fault LED will
never light up.
Dip Switch 2
(Default: O
n)
On:
Enables LFP (Link Fault Pass-through). To enable
the IMC
-101 for LFP, set the SFP port to Auto
mode.
Off:
Disables LFP (Link Fault Pass-through)
Dip Switch 3
(Default:
On)
On:
SFP port in Auto (auto-negotiation) mode
Off:
Forces SFP port to 1000M
Dip Switch 4
Reserved for future use
ATTENTION
When Force mode is used, the LFP function will be disabled.
Содержание
- Edition 6 may 2016 1
- Imc 101g series quick installation guide 1
- Moxa industrial media converter 1
- Features 2
- Overview 2
- Package checklist 2
- Panel layouts of the imc 101g series 3
- Dimensions unit mm 4
- Din rail mounting 4
- Wall mounting optional 5
- Atex and iecex information 6
- Attention 6
- Warning warning 6
- Wiring requirements 6
- Attention 7
- Grounding the imc 101g 7
- Wiring the alarm contact 8
- Wiring the redundant power inputs 8
- 100 1000baset x ethernet port connection 9
- Attention 9
- Communication connections 9
- Basesfp fiber port 10
- Baset x ethernet port connection 10
- Redundant power inputs 10
- Alarm contact 11
- Attention 11
- Imc 101g dip switch setting 11
- Auto mdi mdi x connection 12
- Auto negotiation and speed sensing 12
- Dual speed functionality and switching 12
- Led indicators 12
- Alarm contact one relay output with current carrying capacity of 1 a 24 vdc resistive 13
- Auto negotiation takes place when an rj45 cable connection is made each time a link is enabled the imc 101g advertises its capability for using 10 mbps 100 mbps or 1000 mbps transmission speeds with the device at the other end of the cable expected to advertise similarly depending on what type of device is connected this will result in agreement to operate at a speed of 10 mbps 100 mbps or 1000 mbps 13
- Dip switches port break alarm mask link fault pass through sfp an force 13
- If an imc 101g s rj45 ethernet port is connected to a non negotiating device it will default to 10 mbps speed and half duplex mode as required by the ieee 802 u standard 13
- Interface rj45 ports 10 100 1000baset x auto negotiation speed f h duplex mode and auto mdi mdi x connection 13
- Led indicators pwr1 pwr2 fault 10 100m tp port 1000m tp and sfp port 13
- Optical fiber 1000basesx lsx lx lh lhx zx ezx 13
- Sfp ports 1000base sfp slot 13
- Specifications 13
- Supports sfp 1g series module only 13
- Technology standards ieee802 802 u 802 x 802 z ab link fault pass through 13
Похожие устройства
- Moxa IMC-101G-T-IEX Технические характеристики
- MartinLogan Motion Vision X Руководство пользователя
- MartinLogan Motion 60XT Руководство пользователя
- MartinLogan Motion 50XT Руководство пользователя
- Moxa IMC-P101-M-SC Инструкция по эксплуатации
- Moxa IMC-P101-M-SC Технические характеристики
- Moxa IMC-P101-M-SC-T Инструкция по эксплуатации
- Moxa IMC-P101-M-SC-T Технические характеристики
- Moxa IMC-P101-M-ST Инструкция по эксплуатации
- Moxa IMC-P101-M-ST Технические характеристики
- Moxa IMC-P101-M-ST-T Инструкция по эксплуатации
- Moxa IMC-P101-M-ST-T Технический паспорт
- MartinLogan Motion 30 Руководство пользователя
- Moxa IMC-P101-S-SC Инструкция по эксплуатации
- Moxa IMC-P101-S-SC Технические характеристики
- Moxa IMC-P101-S-SC-T Инструкция по эксплуатации
- Moxa IMC-P101-S-SC-T Технические характеристики
- MartinLogan Motion 20 Руководство пользователя
- Moxa IMC-P101-S-ST Инструкция по эксплуатации
- Moxa IMC-P101-S-ST Технические характеристики