Moxa DA-681A-I-SP [10/79] Linux users

Moxa DA-681A-I-DPP-T-LX [10/79] Linux users
DA-681A Series Linux Software Configuration
2-3
Linux Users
From a Linux machine, use the ssh command to access the DA-681A-LX’s console utility via SSH.
#ssh 192.168.3.127
Select yes to open the connection.
[root@bee_notebook root]# ssh 192.168.3.127
The authenticity of host ‘192.168.3.127 (192.168.3.127)’ can’t be established.
RSA key fingerprint is 8b:ee:ff:84:41:25:fc:cd:2a:f2:92:8f:cb:1f:6b:2f.
Are you sure you want to continue connection (yes/no)? yes_
Adjusting the System Time
The DA-681A-LX has two time settings. One is the system time, and the other is provided by an RTC (Real Time
Clock) built into the DA-681A- LX’s hardware.
Setting the Time Manually
Use the date command to query the current system time or set a new system time. Use hwclock to query the
current RTC time or set a new RTC time.
Use the following command to set the system time.
# date MMDDhhmmYYYY
MM: Month
DD: Date
hhmm: Hour and Minute
YYYY: Year