Candy CCFE 300 RU [19/27] English instruct ion for use chest freezers
![Candy CCFE 300 RU [19/27] English instruct ion for use chest freezers](/views2/1199023/page19/bg13.png)
English Instruct ion for use CHEST FREEZERS
fiCONS91214
3
GB
Directions for use
In the following, you will find all the important information
for the use of your appliance.
The instructions for use apply to several models, which is
why details of the information may differ according to the
type of the appliance.
1 Installation (Choice of position for installation)
Strictly avoid high ambient temperatures and direct
sunlight. We advise you to place your appliance in a cool,
well aired, dry room. Installation in the immediate vicinity of
a heat source (heating, oven etc.) is highly inappropriate
(increased compressor performance would be necessary
and, as a result, energy consumption would be considerably
higher).
If the installation near a heat source cannot be avoided, a
suitable insulation plate must be fitted between the
appliance and the heat source (do not use asbestos), or
the following minimum distances must be observed:
• from gas
or electric cooker 3 cm
• from radiator or oven 5 cm
• from a wall, piece of furniture or
another appliance 2 cm
Never obstruct the ventilation grid
Larger chest freezers are equipped with a ventilation grille
(k) located below on one side. These appliances can be
placed directly against a wall or a piece of furniture but not
with the side protected with the ventilation grille.
Freezers without ventilation grid
Leave sufficient space between the rear of the appliance
and the wall to ensure that outward flow of warm air is able
to escape.
The appliance must be placed horizontally and on a
levelled base. Only this
way can an impeded circuit of the
refrigerant and optimum function be ensured.
IMPORTANT!
Leave the appliance stand in the final position for at
least 2 hours before switch ing it on, so that the
refrigerant circuit stabilises and no operating problems
occur.
The odour which is typical of all new appliances is easy to
remove.
Thoroughly clean the interior compartment with a mixture of
lukewarm water and vinegar .
Do not use washing liquids, sharp or granular cleaning
implements, or any cleaning products containing soda.
Before connecting the appliance, make sure that the inner
area – especially the corners – is absolutely dry.
Danger warning
Depending on its composition, the refrigerant is easily
inflammable. The refrigerant circuit is hermetically sealed
and the density has been subject to repeated tests.
An improper intervention can cause acute fire hazard.
Omit any mechanical influence on the cooling system,
especially on the condenser as far as available.
With some appliances the condenser is built into the
external wall.
Interventions on the cooling system must be carried out by
professional and authorised personnel only.
IMPORTANT!
Escaping refrigerant can injure your eyes.
In the event of eye contact with the refrigerant, wash your
eyes instantly under plenty of running water and
call/consult an eye specialist immediately.
KLIMATE CLASSES
The appliance, according to its climate category, is meant
for use at certain room temperatures.
These temperatures should not be exceeded! The climate
category for your particular appliance is marked on the
rating plate. The categories are:
name of climate
category
suitable
room temperatures
SN
ST
T
+ 10° C to + 32°C
+ 16° C to + 32°C
+ 18° C to + 38° C
+ 18° C to + 43° C
2 Rating plate
The rating plate (with technical data) is located on the
housing (D) at the rear of the appliance.
Take a note of the technical data
Copy the technical data from the rating plate to here so that
it is at any time readily available, without having to move
the appliance
Model/Type …………….…………………………
Gross capacity ……………………………….litres
Net capacity ………………….……………litres
Operating voltage ………………….……...…...V-50Hz
Maximum absorbed power(W)..……………….Watt
Safety (A) ……………….....………………......Amp
Energy consumption…………………………....kWh/24h
Freezing capacity …………………………….....kg/24h
3 Connection to power supply
Your appliance must be connected to a power socked with
grounded connection, which is conform to the respective
standards and has been installed by an authorised
specialist.
Before you connect the plug of the appliance with the
power socket, make absolutely sure that
the voltage (V) on the appliance’s data-plate corresponds
with that of your mains.
If the voltage differs, notify the after-sales-service or your
dealer immediately, and do not on any account connect the
appliance to the mains.
4 Switching on / off temperature selection
(Thermostat) (l)
The temperature control switches the appliance on and off
and controls/sets the cooling temperature.
To prevent temperature being accidentally modified, the
control is intentionally resistant to turning. To vary the
setting, we recommend to use a coin or screwdriver.
N
Содержание
- Chest freezer 1
- Модели 1
- Модельдер 1
- Морозильник ларь 1
- Мұздатқыш қобди 1
- English instruction for use chest freezers 17
- Electrical safety instruction warning this appliance must be earthed if the mains lead of the appliance is fitted with a plug 18
- English instruction for use chest freezers 18
- If the fitted plug is not suitable for your socket outlet then it should be cut off and disposed of in order to avoid a possible shock hazard should it be inserted into a 13a socket elsewhere a suitable alternative plug should then be fitted to the cable the wires in this mains lead are coloured in accordance with the following code 18
- If the mains lead of this appliance is fitted with a bs 1363a 13 amp fused plug to change a fuse in this type of plug use a a s t a approved fuse to bs 1362 type and proceed as follow 1 remove the fuse cover a 2 remove the fuse b 3 fit replacement fuse into plug 4 refit the fuse cover 18
- The fuse cover mast be refitted when changing a fuse and if the fuse cover is lost the plug must not be used until a correct replacement is fitted correct replacements are identified by the colour insert or the colour embossed in words on the base of the plug replacement fuse cover are available from your local electrical store 18
- The yellow green wire must be connected to the terminal in the plug which s marked with the letter e or by the earth symbol or coloured green or yellow green 2 the blue wire must be connected to the terminal which is marked with the letter n or coloured black 3 the brow wire mast be connected to the terminal which is marked with the letter l or coloured red 18
- 10 c to 32 c 16 c to 32 c 18 c to 38 c 18 c to 43 c 19
- English instruct ion for use chest freezers 19
- English instruction for use chest freezers 20
- English instruction for use chest freezers 21
- English instruction for use chest freezers 22
- English instruction for use chest freezers 23
- Storage table chest freezers 24
- Control panel versions fig 4 25
- English components 25
Похожие устройства
- Candy FCL 614/6 GH Инструкция по эксплуатации
- Candy FPE 629/6 NX Инструкция по эксплуатации
- Candy CLG 64 SPTF Инструкция по эксплуатации
- Candy CLGC 64 SPBA Инструкция по эксплуатации
- Candy GV42 128DC1-07 Инструкция по эксплуатации
- Теплодар Сибирский утес 20 ЛП Руководство по эксплуатации
- Теплодар Сибирь 20 ЛК Руководство по эксплуатации
- Теплодар Сибирь 20 ЛНЗП Руководство по эксплуатации
- Теплодар Сибирь 20 ЛРК Руководство по эксплуатации
- Теплодар Сибирь 30 ЛК Руководство по эксплуатации
- Теплодар Сибирь 20 ЛК Панорама Руководство по эксплуатации
- Теплодар Сибирь 20 ЛРК Панорама Руководство по эксплуатации
- Теплодар Сибирь 20 ЛНЗ Панорама Руководство по эксплуатации
- Теплодар Сибирь 30 ЛК Панорама Руководство по эксплуатации
- Теплодар Сибирь 30 ЛНЗП Панорама Руководство по эксплуатации
- Теплодар Сибирский утес 20 ЛП ПРОФИ Руководство по эксплуатации
- Теплодар Сибирский утес Панорама 20 ЛП ПРОФИ Руководство по эксплуатации
- Теплодар Русь 9 ЛУ Руководство по эксплуатации
- Теплодар Русь 9 Л Руководство по эксплуатации
- Теплодар Русь 12 ЛУ Руководство по эксплуатации