Moxa V2201-E1-T-LX [15/21] Stopping an alarm action

Moxa V2201-E1-T-LX [15/21] Stopping an alarm action
Moxa Proactive Monitoring Installing and Using Moxa Proactive Monitoring
1-12
Stopping an Alarm Action
1. To stop an alarm action, select setting and then click the terminate alarm action item to stop the alarm.
NOTE
If the alarm action is triggered, it will
run nonstop until you press the terminate
alarm action to stop it, even if
th
e item returns to normal status.
2. Terminating an alarm action will execute the /sbin/mx_stop_alarm file. You can edit
/sbin/mx_stop_alarm to change the stop alarm action.
The script will set the first digital output to low in the default setting.
root@Moxa:~# vi mx_stop_alarm
#!/bin/sh
mx_dio_control -s 0 -n 1
NOTE
If there is a relay on
the device, the script will turn off the relay in the default setting.