EPM-3112 Specifications
CANbus Communication
Interface: 2 optically isolated CAN2.0A/2.0B compliant ports
CAN Controller: Phillips SJA1000T
Signals: CAN_H, CAN_L
Isolation: 2 kV digital isolation
Speed: 1 Mbps
Connector Type: DB9 male
Physical Characteristics
Weight: 127 g (0.28 lb)
Dimensions: 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in)
Environmental Limits
Operating Temperature: -25 to 55°C (-13 to 131°F), EN 50155 Class T1
EPM-3438 Specifications
Digital Input
Input Channels: 8
Input Voltage: 0 to 30 VDC at 25 Hz
Digital Input Levels for Dry Contacts:
• Logic level 0: Close to GND
• Logic level 1: Open
Digital Input Levels for Wet Contacts:
• Logic level 0: +3 V max.
• Logic level 1: +10 V to +30 V (Source to DI)
Counter Frequency: 2 kHz (DI0 only)
Connector Type: 10-pin screw terminal block (8 DI points, DI Source,
GND)
Isolation: 3 kV optical isolation
Digital Output
Output Channels: 8, sink type, 0 to 30 VDC
Output Current: Max. 200 mA per channel
On-state Voltage: 24 VDC nominal, open collector to 30 VDC
Connector Type: 9-pin screw terminal block (8 DO points, GND)
Isolation: 3 kV optical isolation
Physical Characteristics
Weight: 120 g (0.27 lb)
Dimensions: 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in)
Environmental Limits
Operating Temperature: -40 to 70°C (-40 to 158°F), EN 50155
Class TX
PCI Express Mini Slot
Interface:
• Slot 1: PCI-Express V1.0 (one lane) / USB 2.0
• Slot 2: USB 2.0
USB 2.0 Bus SIM Card Holder: Reserved for cellular applications
EPM-DK02 Specifications
Physical Characteristics
Weight: 125 g (0.28 g)
Environmental Limits
Operating Temperature: -40 to 70°C (-40 to 158°F), EN 50155 Class
TX
EPM-DK03 Specifications
PCI Express Mini Slot
Interface:
• Slot 1: PCI-Express V1.0 (one lane) / USB 2.0
• Slot 2: USB 2.0
USB 2.0 Bus SIM Card Holder: Reserved for cellular applications
Physical Characteristics
Weight: 220 g (0.49 lb)
Dimensions: 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in)
Environmental Limits
Operating Temperature:
w/o wireless module: -40 to 70°C (-40 to 158°F), EN 50155 Class TX
w/ wireless module: -25 to 55°C (-13 to 131°F), EN 50155 Class T1
GPS Interface
Receiver Types:
• 50-channel u-blox 6 LEA-6 receiver
• GPS L1 C/A code
• GALILEO L1 open service (with upgrade)
• SBAS: WAAS, EGNOS, MSAS, GAGAN
Acquisition:
• Cold starts: 28 s
• Warm starts: 28 s
• Aided starts: 1 s
• Hot starts: 1 s
Sensitivity:
• Tracking: -160 dBm
• Reacquisition: -160 dBm
• Cold starts: -147 dBm
Timing accuracy:
• RMS: 30 ns
• 99%: <60 ns
• Granularity: 21 ns
Accuracy:
• Position: 2.5 m CEP
• SBAS: 2.0 m CEP
Protocols: NMEA, UBX binary, max. update rate: 5 Hz (ROM version )
Time Pulse: 0.25 Hz to 1 kHz
Velocity Accuracy: 0.1 m/s
Heading Accuracy: 0.5 degrees
A-GPS: Supports AssistNow Online and AssistNow Ofine, OMA SUPL
compliant
Operational Limits: Velocity: 500 m/s (972 knots)