Moxa V2416-W7E [16/42] Connecting to a serial device

Moxa V2416-T-W7E [16/42] Connecting to a serial device
V2416 Hardware Manual Hardware Connection Description
3-5
Grounding the Unit
SG:
The Shielded Ground (sometimes called Protected Ground) contact is the
central pin of
the power input connector. Connect the SG wire to an appropriate grounded metal surface.
Connecting Data Transmission Cables
This section describes how to connect the V2416 embedded computers to the network and serial devices.
Connecting to the Network
Plug your network cable into the embedded computer’s Ethernet port. The other end of the cable should be
plugged into your Ethernet network. When the cable is properly connected, the LEDs on the embedded
computer’s Ethernet port will glow to indicate a valid connection.
Two 10/100/1000 Mbps Ethernet ports using M12 connectors are located on the front panel. See the figure at
the right for pin assignments.
Pin No. 10/100 Mbps 1000 Mbps
1
TRD3+
2 TRD4+
3 TRD4-
4 ERx- TRD1-
5 ETx+ TRD2+
6 ERx+ TRD1+
7 TRD3-
8 ETx- TRD2-
Connecting to a Serial Device
Use a serial cable to plug your serial device into the embedded computer’s serial port. Serial ports P1 to P4 have
male DB9 connectors and can be configured for RS-232, RS-422, or RS-485 communication by software. The
pin assignments are shown in the following table:
DB9 Male Port RS-232/422/485 Pinouts
Pin RS-232 RS-422 RS-485-4W RS-485-2W
1 DCD TxDA(-) TxDA(-)
2 RxD TxDB(+) TxDB(+)
3 TxD RxDB(+) RxDB(+) DataB(+)
4 DTR RxDA(-) RxDA(-) DataA(-)
5 GND GND GND GND
6 DSR
7 RTS
8 CTS

Содержание

Похожие устройства

Скачать