Moxa MC-7130-MP [3/7] Introduction

Moxa MC-7130-MP [3/7] Introduction
1. Introduction
The hardware components listed in this document have either been proven to provide
up-to-spec performance when used with the Moxa MC-7000 series of embedded computers, or
which share basic design features with such components.
As Moxa computers come with different peripheral options and are engineered to differing
hardware specifications, compatibility issues may sometimes arise. When paired with Moxa’s
MC-7000 series of embedded computers, peripherals from one manufacturer may not work as well
as those made by another. For this reason, Moxa provides this list of compatible components, so
that users can be certain to get the reliability they expect from Moxa’s MC-7000 series.
2. Testing Methods
To validate a component as meeting Moxa standards of quality and environmental tolerances,
five key compatibility tests may be run:
Ambient Temperature Burn-In
Low Temperature Hard Starts
Heat/Humidity Burn-In
Cyclic High-Low Temperature Burn-in
Vibration Test
Ambient Temperature Burn-in
Components are mounted in an MC-7000 computer and run through a series of stress tests at
an ambient temperature of around 25˚C for a specified period of time. Test periods are determined
according to the class of peripherals being tested.
Low Temperature Hard Start
Components are mounted in an unpowered MC-7000 computer and then the system is booted
up from an extremely low temperature. The designated temperature depends on the model being
tested.
Heat/Humidity Burn-in
Components are mounted in an MC-7000 computer, placed in a temperature- and
humidity-controlled enclosure, and then run through the burn-in test for a specific time. The
temperature, humidity, and time targets vary depending on model specification.
Cyclic High-Low Temperature Burn-in
Components are mounted in an MC-7000 computer, placed in a temperature controlled
enclosure, and then put through the burn-in test as temperatures are cycled from very high to very
low and back again over a specified period of time. The target temperatures and time vary
depending on model specifications.

Похожие устройства