Moxa ICF-1150-M-ST-T-IEX [7/9] Attention

Moxa ICF-1150-S-SC [7/9] Attention
- 7 -
Fiber Cable
SC-Port Pinouts
SC-Port to SC-Port Cable Wiring
ST-Port Pinouts
ST-Port to ST-Port Cable Wiring
ATEX and IECEx Information
1. Certification number:
DEMKO 10 ATEX 0917344X
IECEx UL 13.0044X
2. Ambient range: -4C Tamb 8C
3. Certification string: Ex nA IIC T4 Gc
4. Standards covered: EN 60079-0:2012+A11:2013, IEC 60079-0:
6th Ed; EN 60079-15:2010 IEC 60079-15:4th Ed
5. Conditions of safe usage:
The equipment shall only be used in an area of not more than
pollution degree 2, as defined in IEC 60664-1.
The equipment shall be installed in an enclosure that provides a
degree of protection not less than IP54, in accordance with
IEC/EN 60079-15, and accessible only by the use of a tool.
Transient protection shall be provided that is set at a level not
exceeding 140% of the peak rated voltage value at the supply
terminals to the equipment.
The Terminal blocks (J1, J2) are suitable for 12-28 AWG
(3.31-0.08 mm
2
), with torque = 4.5 lb-in. The cross-sectional
area of the PE conductor is Sp=3.31 mm
2
. The conductor used
for grounding is same size as the power conductor.
Conductors suitable for use in an ambient temperature of 91°C
must be used for the power supply terminal.
ATTENTION
This is
a Class 1 laser/LED product. Do not stare into the laser
beam.

Похожие устройства

Скачать