Moxa ICF-1180I-S-ST [8/16] Wiring the redundant power inputs

Moxa ICF-1180I-M-ST [8/16] Wiring the redundant power inputs
- 8 -
Wiring the Redundant Power Inputs
STEP 1: Insert the negative/positive DC wires
into the V
-/V+ terminals.
STEP 2: To keep the DC wires from pulling loose,
use a small
flat-
blade screwdriver to tighten the
wire
-clamp screws on the front of the terminal
block connector.
STEP 3:
Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is located on the ICF
-1280I
’s top
panel.
ATTENTION
Before connecting the ICF
-1180I
to the DC power inputs, make
sure the DC power source voltage is stable.
You should also pay attention to the following:
The temperature rating of the input connection cable should be higher
than 91°C.
The cross sectional area of the ground wire should be at least 3.31
mm
2
.
The terminal block plug should be suitable for 28-12 AWG
(0.0804-3.31 mm
2
) wire and a torque of 4.5 lb-in.