Moxa ioLogik E1242 [5/8] Connecting to the network
![Moxa ioLogik E1211 [5/8] Connecting to the network](/views2/1201060/page5/bg5.png)
- 5 -
Jumper Settings
Models with DIO, AI, or external power channels require configuring the
jumpers inside the enclosure. Remove the screw located on the back
panel and open the cover to configure the jumpers.
DIO mode configurations are
shown above (Default: DO Mode).
Analog mode configurations are
shown above (Default: Voltage
Mode).
DOs on the ioLogik E1213 have 3
possible external (EXT) power
configurations, which are shown to
the right. Only one field power can
be selected at a time (JP10 / 12V JP5
/ 9V JP11)
and
the jumper must be
inserted vertically, not horizontally
(Default: Field Power JP10).
NOTE
The ioLogik E1213 has 4 pure DO channels and 4 hybrid DIO
channels. For the 4 pure DO channels, you can use the jumpers to
select the power configuration output (i.e., field power, 12 V, 9
V). But for the 4 hybrid DIO channels, you cannot use the
j
umpers to select the power configuration output. Instead, you
can only use the jumpers to set the DIO channels to either DI
mode or DO mode.
Mounting
There are two sliders on the back of the unit for DIN rail and wall
mounting.
1. Mounting on a DIN rail: Pull out the bottom slider; latch the unit
onto the DIN-rail, and push the slider back in.
2. Mounting on the wall: Pull out both the top and bottom sliders and
align the screws accordingly.
Connecting to the Network
The ioLogik E1200 has two built-in RJ45 Ethernet ports for connecting
standard direct or cross-over Ethernet cables.
Содержание
- Edition 5 september 2016 1
- Iologik e1200 series quick installation guide 1
- Overview 2
- Package checklist 2
- Specifications 2
- Connecting the power 4
- Installation 4
- Connecting to the network 5
- Jumper settings 5
- Mounting 5
- Analog inputs outputs 6
- Digital inputs outputs 6
- I o wiring 6
- Led indicators 6
- Configuration via web console 7
- Iosearch utility 7
- Relay output form a 7
- Rtd inputs 7
- System configuration 7
- Tc inputs 7
- Active opc server connection 8
- Atex information 8
- Load factory default settings 8
- Modbus address table 8
Похожие устройства
- Moxa ioLogik E1242 Брошюра
- Moxa ioLogik E1242-T Инструкция по эксплуатации
- Moxa ioLogik E1242-T Руководство по аппаратной части
- Moxa ioLogik E1242-T Технические характеристики
- Moxa ioLogik E1242-T Брошюра
- Moxa ioLogik E1260 Инструкция по эксплуатации
- Moxa ioLogik E1260 Руководство по аппаратной части
- Moxa ioLogik E1260 Технические характеристики
- Moxa ioLogik E1260 Брошюра
- Moxa ioLogik E1260-T Инструкция по эксплуатации
- Moxa ioLogik E1260-T Руководство по аппаратной части
- Moxa ioLogik E1260-T Технические характеристики
- Moxa ioLogik E1260-T Брошюра
- Moxa ioLogik E1262 Инструкция по эксплуатации
- Moxa ioLogik E1262 Руководство по аппаратной части
- Moxa ioLogik E1262 Технические характеристики
- Moxa ioLogik E1262 Брошюра
- Moxa ioLogik E1262-T Инструкция по эксплуатации
- Moxa ioLogik E1262-T Руководство по аппаратной части
- Moxa ioLogik E1262-T Технические характеристики