Moxa ioPAC 8500-9-RJ45-C-T [59/66] Mx_fault_led_get

Moxa ioPAC 8020-5-M12-C-T [59/66] Mx_fault_led_get
Developer's Guide for Moxa RTU Controllers Programmer's Guide
2-51
MX_Ready_LED_Get
UINT32 MX_Ready_LED_Get(UINT32 *state);
Gets the ready LED status. The state will be written to the state parameter.
Output Parameters
state
0: Off
1: Green
2: Red (for the ioPAC 8020-C series)
Return Value
Result of the call
MX_Fault_LED_Get
UINT32 MX_Fault_LED_Get(UINT32 *state);
Gets the fault LED status. The state will be written to the state parameter.
Output Parameters
state
Return Value
Result of the call
Notes
ioLogik W5348-C series only
MX_Link_LED_Get
UINT32 MX_Link_LED_Get(UINT32 *state);
Gets the link LED status. The state will be written to the state parameter.
Output Parameters
state
Return Value
Result of the call
Notes
ioLogik W5348-C series only
MX_IO_LED_Get
UINT32 MX_IO_LED_Get(UINT32 *state);
Gets the I/O LED status. The state will be written to the state argument.
Output Parameters
state
0: Off
1: Green
2: Red
Return Value
Result of the call
Notes
ioPAC 8020-C series only