2-3
c. Mounting with the fixed plate
If nuts, gaskets, and spring washers cannot be used
when mounting on the ceiling, use the VP
-FP1 fixed
plate. Drill the green
dotted-line holes and the 4
camera mounting screw holes in the sticker, and
then put the VP
-FP1 inside the hole. Use the 2
countersink screws to mount the VP
-SP1. Finally,
mount the VPort P06
-1MP-M12 on the fixed plate
with 4 indented hexagon head tapping
screws.