Moxa VPort P06-1MP-M12-CAM42-CT-T [54/65] Event alarm

Moxa VPort P06-1MP-M12-CAM60 [54/65] Event alarm
VPort P06-1MP-M12 System Configuration
4-32
Setting Description Default
Sun Mon Tue
Wed Thu Fri
Sat
Select the weekday for scheduling event alarms. None
Begin 00:00 Set the start time of the event alarm. 00:00
Duration 00:00 Set the duration for the event alarm to be active. 00:00
NOTE
Administrators can use the following steps to set up an event schedule:
1.
Select Event Type
2.
Enable “Event Alarms are active based on weekly schedule”
3.
Select the weekday
4.
Set the start time
5.
Set the duration this event will be active.
6.
Save
Event Alarm
Four kinds of event alarm are provided by the VPort for building an intelligent video surveillance system.
Alarm Type Triggered Condition Triggered Action
Video Motion Detection
(VMD)
VMD 1
VMD 2
VMD 3
Email
FTP
HTTP Event Server
CGI Event The CGI trigger message Email
FTP
HTTP Event Server
Camera Tamper Event Camera Tamper Email
FTP
HTTP Event Server

Содержание

Похожие устройства

Скачать