Braun SI 18830 [10/70] H cleaning the anticalc valve

Braun SI 18830 [10/70] H cleaning the anticalc valve
10
Spray function
Press the spray button (5).
Dry ironing
Set the steam regulator (6) on position «0»
(= steam off).
D Automatic shut-off
(SI 18.895 and SI 18.835 models only)
The «auto-off» mechanism causes a slight
rattling noise during ironing. This is normal
and in no case indicates a fault of the iron.
The red «auto-off» light (9) will flash when
the automatic shut-off is activated.
This happens when the iron has rested
– horizontally
on its sole plate for about
30 seconds or
– vertically on its heel rest for about
8 minutes.
To turn on the iron again, just move it.
When the «auto-off» pilot light stops
flashing, the electrical power is on again.
The automatic shut-off will be activated
approximately 2 minutes after the iron is
plugged into a socket.
E Textile Protector
(SI 18.895 and SI 18.890 models only)
Before attaching the Textile Protector (11)
for the first time, iron approximately 2
minutes without Textile Protector. The
Braun Textile Protector protects delicate
fabrics from heat damage and makes it
possible to iron most dark fabrics without
an intermediate cloth.
A special coating avoids shiny patches.
However, in order not to damage the
coating, avoid ironing over e.g. zippers,
metal buttons/rivets or strass with the
Textile Protector attached.
To check the reaction of your fabrics
before you start ironing, we recommend
that you iron a small section of material on
the reverse side. With the Protector, you
are able to iron delicate fabrics with the
temperature setting within the solid red
range so that you can use all steam
functions your iron offers.
After having attached the Textile
Protector, wait about 1 1/2 minutes before
you start ironing. Always store your iron
with the Textile Protector detached.
F After ironing
Unplug the iron and turn the steam
regulator to position «0». To prolong the
life of the iron, empty the water tank.
Store the cool iron in a dry place always
standing on its heel rest.
G Maintenance and cleaning
To clean the sole plate, use steel wool.
Never use a scouring pad, vinegar or other
chemicals. To clean the soft material on
the handle, use soapy water.
H Cleaning the anticalc valve
The anticalc valve located on the lower
end of the steam regulator has to be
decalcified regularly (e.g. whenever steam
development is insufficient). For this, the
water tank has to be empty.
Removing the steam regulator with the
anticalc valve
Turn the steam regulator clockwise
towards the steam setting «6». Keep
on turning firmly beyond the resistance
until the steam regulator is lifted. When
positioned at
x
, pull it out vertically.
Do not touch the anticalc valve at its lower
end. Immerse the anticalc valve in vinegar
(not vinegar essence) or lemon juice for
a minimum of 30 minutes. Brush off
remaining residues and rinse under
running water (fig. H, 1-7).
Re-inserting the steam regulator
When re-inserting the steam regulator,
make sure the steam regulator base still
points on setting
x
(fig. H 8). Firmly push
down the steam regulator until it turns
back to setting «6« (fig. H) where it
catches.
Notice: The iron must never be used
without steam regulator.
I Decalcifying/anticalc system
In order to clean the steam chamber from
residues, decalcify it as shown in picture
section I, 1-8.
Caution: Hot water and steam will come
out from the sole plate when the steam
regulator is turned clockwise beyond
setting «6».
Wait for the sole plate to cool down, then
clean it as described above. Then refill the
tank with water, heat up the iron and press
the Precision Shot button 4 times to rinse
the iron before ironing (fig. I, 9-13).
Do not use commercial decalcifiers, they
may damage the iron.
4679357_SI1800_S06-72_MN Seite 10 Montag, 5. November 2007 10:56 10

Содержание

Spray function Press the spray button 5 Dry ironing Set the steam regulator 6 on position 0 steam off D Automatic shut off S118 895 and S118 835 models only The auto off mechanism causes a slight rattling noise during ironing This is normal and in no case indicates a fault of the iron The red auto off light 9 will flash when the automatic shut off is activated This happens when the iron has rested horizontally on its sole plate for about 30 seconds or vertically on its heel rest for about 8 minutes To turn on the iron again just move it When the auto off pilot light stops flashing the electrical power is on again The automatic shut off will be activated approximately 2 minutes after the iron is plugged into a socket E Textile Protector S118 895 and S118 890 models only Before attaching the Textile Protector 11 for the first time iron approximately 2 minutes without Textile Protector The Braun Textile Protector protects delicate fabrics from heat damage and makes it possible to iron most dark fabrics without an intermediate cloth A special coating avoids shiny patches However in order not to damage the coating avoid ironing over e g zippers metal buttons rivets or strass with the Textile Protector attached To check the reaction of your fabrics before you start ironing we recommend that you iron a small section of material on the reverse side With the Protector you are able to iron delicate fabrics with the temperature setting within the solid red range so that you can use all steam functions your iron offers After having attached the Textile Protector wait about 1 1 2 minutes before you start ironing Always store your iron with the Textile Protector detached F After ironing Unplug the iron and turn the steam regulator to position 0 To prolong the life of the iron empty the water tank Store the cool iron in a dry place always standing on its heel rest 10 G Maintenance and cleaning To clean the sole plate use steel wool Never use a scouring pad vinegar or other chemicals To clean the soft material on the handle use soapy water H Cleaning the anticalc valve The anticalc valve located on the lower end of the steam regulator has to be decalcified regularly e g whenever steam development is insufficient For this the water tank has to be empty Removing the steam regulator with the anticalc valve Turn the steam regulator clockwise towards the steam setting 6 Keep on turning firmly beyond the resistance until the steam regulator is lifted When positioned at pull it out vertically Do not touch the anticalc valve at its lower end Immerse the anticalc valve in vinegar not vinegar essence or lemon juice for a minimum of 30 minutes Brush off remaining residues and rinse under running water fig H 1 7 Re inserting the steam regulator When re inserting the steam regulator make sure the steam regulator base still points on setting fig H 8 Firmly push down the steam regulator until it turns back to setting 6 fig H where it catches Notice The iron must never be used without steam regulator I Decalcifying anticalc system In order to clean the steam chamber from residues decalcify it as shown in picture section I 1 8 Caution Hot water and steam will come out from the sole plate when the steam regulator is turned clockwise beyond setting 6 Wait for the sole plate to cool down then clean it as described above Then refill the tank with water heat up the iron and press the Precision Shot button 4 times to rinse the iron before ironing fig I 9 13 Do not use commercial decalcifiers they may damage the iron

Скачать