Timberk TFHS20TL.SN [8/12] Performance parameters main features

Содержание

Похожие устройства

15 Do not use the fan heater in rooms with increased humidity nearby bath rooms shower bath pools ponds i e in places where it may be tipped over into water or water or water drops may contact it 16 It is forbidden to mount the unit next to an electric outlet provided that the hot air flow will contact it 17 Upon switching off the fan heater at first it is necessary to turn off the heating element leaving the fan operating for at least 3 minutes Only then you can switch off the unit completely and unplug the power cord 18 The heater is not designed for industrial application It is used only as an additional means of heating Make sure to take this information into consideration 3 Performance parameters Main features 1 Thanks to the modern design the fan heater is convenient to be placed in any room where additional air heating is required 2 Durable and flameproof spiral heating element provides quick and effectiveair heating 3 Low noise turbo motor 4 Towel rail that comes with the fan heaterallows todry wetthings Technical characteristics Technical characteristics are shown in Table 1 Table 1 Voltage V Hz 2000 Maximum current A 9 1 Net weight kg 429x313x113 2 78 Gross weight kg 3 10 For a detailed description of technical parameters and characteristics go to www timberk ru or contact TIMBERK HHA Company official dealers 4 Operation conditions 1 Do not install the unit on unstable or uneven surfaces 2 To prevent an electric shock do not connect and disconnect the power cord plug out of an outlet by wet hands otherwise it may harm your health 8 www timberk ru электрический спиральный тепловентилятор Never use the unit in a horizontal or inclined position 5 Description of the fan heater I Poweron indicator 2 Appliance body 3 Control panel located on the side of the device 4 Airflowoutletgrill 5 Hangerfortowels 6 Scope of delivery 1 Fan heater 1 pc 2 Fan heater mounting bracket 1 pc 3 Fixture for hangers 1 pc 4 Hanger 2 pcs 5 Operation manual 1 pc 6 Guarantee card 1 pc 7 Package 1 pc 220 240 50 Maximum power W Overall dimensions mm 3 For normal operation of the unit the mains voltage must be sufficient in strict compliance with technical parameters indicated on the unit 4 The unit must be mounted vertically only 5 Do not use the unit in a room with high dust content Otherwise high amount of dust in the unit may cause its failure and voiding of guarantee maintenance Fig 1 7 Assembly and installation I The unit can operate only wall mounted vertically The unit cannot be mounted on a ceiling 2 Select an area next to an outlet but not directly above it and provide minimum distances from the wall ceiling and floor 3 Drill two holes as shown in Fig 3 and make sure that they are located on one horizontal line Using building dowels and wood screws secure bracket C on the wall 4 Insert unit A into bracket C Make a mark in point F Fug 4 Remove the unit and drill a hole in point F Insert the unit into the bracket Make sure the bracket goes to the unit s slot completely Attach the unit to the bracket by screw E Fig 4

Скачать