Switch Mode
You can choose how the VS0801H behaves when a new input
source is connected to it. By default the Next switch mode setting
is enabled. Use the commands below to select a different mode.
There are three Switch Modes:
Next - Switch priority is placed on the next port that has a new
source device connected to it. (default)
Default - The switch behaves normally without automatic
switching.
Auto - Places priority on a selected port so that when a source is
connected to the said port, the VS0801H automatically switches
to it, and the port can not be changed until the source is
unplugged or auto switching mode is disabled with the default
command.
In addition, the Go To function enables the VS0801H to switch to
the next port with a powered on source device when the current
input source device is powered off.
Содержание
- Port hdmi switch p.1
- Emc information p.2
- Vs0801h user manual p.4
- Telephone support p.4
- Technical support p.4
- Online registration p.4
- For north american technical support p.4
- For international online technical support including troubleshooting documentation and software updates http support aten com p.4
- Package contents p.5
- Overview p.6
- Features p.7
- Cables p.8
- System requirements p.8
- Source devices s p.8
- Display device p.8
- Vs0801h front view p.9
- Components p.9
- Vs0801h rear view p.10
- Ir remote control p.11
- Installing the rs 232 controller p.12
- Installation p.12
- Installation diagram p.13
- Source device selection p.14
- Remote control selection p.14
- Manual selection p.14
- Auto switch p.15
- Rs 232 serial interface p.16
- Configuring the serial port p.16
- Verification p.16
- The formulas for switch port commands are as follows p.17
- The following tables show the possible values for the input port port number and control commands p.17
- Switch port commands p.17
- Switch command input port port number enter p.17
- Switch command control enter p.17
- Sw off enter p.17
- Sw i02 enter p.17
- Sw enter p.17
- For example to turn off the output port type the following p.17
- For example to switch to the next port type the following p.17
- For example to switch to input port 02 type the following p.17
- The input port and output port command strings are interchangeable for example sw i02 o01 can also be sw o01 i02 p.18
- The input output port command string can be skipped and the default value s will be used for example to switch the input port 01 to the default output port 01 simply enter sw i01 p.18
- The following table shows the available command list p.18
- Note 1 each command string can be separated with a space p.18
- Switch mode command p.19
- The following tables show the values for switch mode p.20
- The following table lists the available commands p.20
- Note 1 each command string can be separated with a space p.20
- Read command p.21
- Powering off and restarting p.22
- Rs 232 control tool operation p.23
- Overview p.23
- Installing the rs 232 control tool p.23
- Installing net framework 2 p.23
- Before you begin p.23
- Gui main page p.28
- Switch port p.29
- For example to turn off the display port type the following p.30
- For example to switch to the next input port type the following p.30
- For example to switch to input port 02 type the following p.30
- These actions can also be performed by keying the command into the text box and clicking send p.30
- The following table shows the possible values for switch commands p.30
- The available formulas for switch port commands are as follows p.30
- Switch port commands p.30
- Switch command input command port number enter p.30
- Switch command control enter p.30
- Sw off enter p.30
- Sw i02 enter p.30
- Sw enter p.30
- Possible values p.30
- The port number command string can be skipped and p.31
- The default value will be used p.31
- Switch port command table p.31
- Each command string can be separated with a space p.31
- After commands are sent acknowledge messages are returned p.31
- Acknowledge p.31
- Switch mode p.32
- The following table lists the available commands p.34
- Read info p.35
- Read command p.35
- Rs 232 setting p.36
- Specifications p.37
- Limited warranty p.38
Похожие устройства
-
Aten VS201Руководство пользователя -
Aten VS201Описание и спецификации продукта -
Aten VS881Руководство пользователя -
Aten VS881Описание и спецификации продукта -
Aten VS881Краткое руководство по установке -
Aten VS231Описание и спецификации продукта -
Aten VS231Краткое руководство по установке -
Aten VS491Руководство пользователя -
Aten VS491Описание и спецификации продукта -
Aten VS291Руководство пользователя -
Aten VS291Описание и спецификации продукта -
Aten VS461Руководство пользователя