Power indicator doesn't
work and there is no air
and mist
SYMPTOMS CAUSE
ACTION ITEMS
The unit isn't connected to
the mains power supply
Connect the humidifier to the
mains power supply
The humidifier isn't turned on
English
ATTENTION:
1 To avoid an electric shock, do not touch the mains when your hands are wet.
2 You must not obstruct the mist outlet/nozzle with any object.
3 If the power cord or the product is damaged, please do not use the product.
It must be replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
5.9. TROUBLESHOOTING
The display is on, the unit
with air but no mist
Switch on the unit
There is no water in the
water tank
Fill the water tank
with water
Unpleasant-smelling mist
New unit
Dirty water or stored too
long in the water tank
Open water tank, put it in
the shade for 12 hours
Clean the water tank, fill
with clean water
The display is on, but the
unit doesn't emit air or mist
Too much water in the
base flume
The humidity level in the
room is higher than the auto
humidity level of the humidifier
Increase the humidity level
of the humidifier
Empty the flume then close
the water tank cap.
Small fog output
Dirty ultrasonic transducer
Dirty water or long-time to
store water in water tank
Clean the transducer
Clean the water tank, fill
clean water in.
Strange noise
Other malfunctions
Caused by insufficient water
in water tank
Fill water tank with water.
Vibration from the surface it
is resting on
Place on a stable level
surface.