Safety Measures
The instruments FLUKE T100/T120/T140 have
been constructed and verified in compliance
with the safety measures for voltage testers
and have left the factory in safe and perfect
condition.
In order to avoid electrical shock, the valid
safety and VDE regulations regarding ex-
cessive contact voltages must receive ut-
most attention, when working with volta-
ges exceeding 75V (60V) DC or 50V
(25V)rms AC. The values in brackets are
valid for spezial ranges (for example medi-
cine and agriculture).
The detector shall not be used, if the bat-
tery box is open.
Prior to each test, ensure the proper con-
dition of the measuring line and the mea-
suring instrument, e.g. broken cables or
leaking batteries.
Prior to measurement ensure that the test
leads and the test instrument are in per-
fect condition.
When using this instrument only the hand-
les of the probes may be touched .
This instrument may only be used within
the ranges specified (see 6.0 Technical
Data) and within voltage systems up to
690V
The measuring instrument may be used only in
the measuring circuit category it has been de-
signed for!
Instrument's faultless functionality must be veri-
fied prior to every use.
1) Short-circuit the probes. The Rx/Ohm LED
must light up. If not, remove/replace the
batteries.
2) Test the voltage tester on a known voltage
source.
Prior to usage ensure perfect instrument
function (e.g. on known voltage source).
The voltage testers may no longer be used
if one or several functions fail or if no
functionalityis indicated.
Fluke T100/120/140
Safety Measures
4
Содержание
- Fluke t100 120 140 introduction 2
- Measuring circuit cate gory cat iv 2
- Measuring circuit category cat iii 2
- References marked on instru ment or in instruction manual 2
- Fluke t100 120 140 introduction 3
- Introduction scope of supply 3
- Fluke t100 120 140 safety measures 4
- Safety measures 4
- Appropriate usage 5
- Fluke t100 120 140 safety measures 5
- Control elements and connections 6
- Fluke t100 120 140 control elements 6
- Carrying out measurements 7
- Fluke t100 120 140 users manual 7
- Preparation and safety measures 7
- Voltage test 7
- Fluke t100 120 140 users manual 8
- Not t140 vde 8
- Single pole phase test 8
- Voltage test with rcd trip test 8
- Continuity test diode test 9
- Fluke t100 120 140 users manual 9
- Only t140 vde 9
- Restistance test only t140 t140 vde 9
- Voltage test with rcd trip test 9
- Fluke t100 120 140 users manual 10
- Measurement point illumination 10
- Rotary field indication 10
- Battery replacement 11
- Calibration interval 11
- Cleaning 11
- Fluke t100 120 140 maintenance 11
- Maintenance 11
- Fluke t100 120 140 maintenance 12
- Fluke t100 120 140 technical data 13
- Technical data 13
- Fluke t100 120 140 warranty 14
Похожие устройства
- Fluke t140/vde Инструкция по эксплуатации
- Fluke -28iiex Инструкция по эксплуатации
- Fluke 319 Инструкция по эксплуатации
- Fluke 317 Инструкция по эксплуатации
- Fluke 117 Инструкция по эксплуатации
- Fluke 15b Инструкция по эксплуатации
- Fluke 17b Инструкция по эксплуатации
- Fluke 421d Инструкция по эксплуатации
- Fluke 411d Инструкция по эксплуатации
- Fluke -62 max+ Инструкция по эксплуатации
- Fluke -62 max Инструкция по эксплуатации
- Forester bs1000 Инструкция по эксплуатации
- Forester 5111-18 Инструкция по эксплуатации
- Forester 5300-3s Инструкция по эксплуатации
- Forester 4735 Инструкция по эксплуатации
- Frezerr pc 777с 00000047507 Инструкция по эксплуатации
- Frezerr pc 888a 00000047509 Инструкция по эксплуатации
- Frezerr pc 888a 00000047508 Инструкция по эксплуатации
- Frezerr pc 777с 00000047506 Инструкция по эксплуатации
- Frico pa4225a Инструкция по эксплуатации