Fluke t140/vde [2/14] Fluke t100 120 140 introduction
![Fluke t140/vde [2/14] Fluke t100 120 140 introduction](/views2/1230683/page2/bg2.png)
References marked on instru-
ment or in instruction manual:
Warning of a potential danger, comply with
instruction manual.
Reference. Please use utmost attention.
Caution! Dangerous voltage. Danger of
electrical shock.
Continuous double or reinforced insulation
complies with category II IEC 61140.
Symbol for the marking of electrical and electronic
equipment (WEEE Directive 2002/96/EC).
Suitable for live working.
VDE-approved, built- in compliance with
the valid directives.
Conformity symbol, the instrument com-
plies with the valid directives. It complies
with the EMV Directive (89/336/EEC). It
also complies with the Low Voltage Directi-
ve (73/23/EEC).
Measuring Circuit
Category CAT III:
In addition to category II, the measuring circuit
category III includes electric equipment subject
to special demands with reference to safety
and availability.
Examples: House installations, protective
equipment, outlets, switches...
Measuring Circuit Cate-
gory CAT IV:
Electric equipment, for which lightning voltage
must also be taken into consideration, belongs
to category IV. This includes, e.g. the connecti-
on to overhead circuits, underground cables to
water pumps...
The instruction manual contains informati-
on and references, necessary for safe
operation and maintenance of the instru-
ment. Prior to using the instrument read
the instruction manual and comply with it
in all sections.
Failure to read the instruction manual or to
comply with the warnings and references
contained herein can result in serious bo-
dily injury or instrument damage.
Fluke T100/120/140
Introduction
2
Содержание
- Fluke t100 120 140 introduction 2
- Measuring circuit cate gory cat iv 2
- Measuring circuit category cat iii 2
- References marked on instru ment or in instruction manual 2
- Fluke t100 120 140 introduction 3
- Introduction scope of supply 3
- Fluke t100 120 140 safety measures 4
- Safety measures 4
- Appropriate usage 5
- Fluke t100 120 140 safety measures 5
- Control elements and connections 6
- Fluke t100 120 140 control elements 6
- Carrying out measurements 7
- Fluke t100 120 140 users manual 7
- Preparation and safety measures 7
- Voltage test 7
- Fluke t100 120 140 users manual 8
- Not t140 vde 8
- Single pole phase test 8
- Voltage test with rcd trip test 8
- Continuity test diode test 9
- Fluke t100 120 140 users manual 9
- Only t140 vde 9
- Restistance test only t140 t140 vde 9
- Voltage test with rcd trip test 9
- Fluke t100 120 140 users manual 10
- Measurement point illumination 10
- Rotary field indication 10
- Battery replacement 11
- Calibration interval 11
- Cleaning 11
- Fluke t100 120 140 maintenance 11
- Maintenance 11
- Fluke t100 120 140 maintenance 12
- Fluke t100 120 140 technical data 13
- Technical data 13
- Fluke t100 120 140 warranty 14
Похожие устройства
- Fluke -28iiex Инструкция по эксплуатации
- Fluke 319 Инструкция по эксплуатации
- Fluke 317 Инструкция по эксплуатации
- Fluke 117 Инструкция по эксплуатации
- Fluke 15b Инструкция по эксплуатации
- Fluke 17b Инструкция по эксплуатации
- Fluke 421d Инструкция по эксплуатации
- Fluke 411d Инструкция по эксплуатации
- Fluke -62 max+ Инструкция по эксплуатации
- Fluke -62 max Инструкция по эксплуатации
- Forester bs1000 Инструкция по эксплуатации
- Forester 5111-18 Инструкция по эксплуатации
- Forester 5300-3s Инструкция по эксплуатации
- Forester 4735 Инструкция по эксплуатации
- Frezerr pc 777с 00000047507 Инструкция по эксплуатации
- Frezerr pc 888a 00000047509 Инструкция по эксплуатации
- Frezerr pc 888a 00000047508 Инструкция по эксплуатации
- Frezerr pc 777с 00000047506 Инструкция по эксплуатации
- Frico pa4225a Инструкция по эксплуатации
- Frico pa4220a Инструкция по эксплуатации