General instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The guarantee is only valid if the
Thermozone units are used in the manner
intended by the manufacturer and in
accordance with the Frico installation and
maintenance instructions.
Application area
The SF air curtain unit is intended for
installation in curved doorways.
SF is installed to the side of the entrance.
Operation
Air is drawn in at the side of the unit and
blown out towards the entrance so that it
shields the door opening and minimizes heat
loss. To achieve the optimum curtain effect
the unit must extend the full height of the
door opening.
The grille for directing exhaust air is
adjustable and is normally angled towards the
curved doorway to achieve the best protection
against incoming cold air.
The airflow can be adjusted by use of the fan
speed selector.
The efficiency of the air curtain(s) depends
on the air temperature, pressure differences
across the doorway and any wind pressure.
NOTE!Negativepressureinthebuilding
considerably reduces the efficiency of the air
curtain. The ventilation should therefore be
balanced!
Installation
The unit is installed as floor standing on
adjustable feet that make it possible to
compensate for possible irregularities in the
floor. The feet are bolted to the floor and
covered by a covering edge. SF is mounted
to the left of the door seen from inside the
building and should also be secured to the
door. SF has a curved design that integrates
neatly with the door. Extension is possible up
to 3900 mm (extension without fans).
Ensure that the service hatch is accessible
and can be fully opened.
See sketches p.2-3.
Electrical installation
Electrical connection may only be carried
out by an authorized electrician, and in
accordance with these instructions and the
applicable regulations.
1. The service hatch is opened by slackening
off the screws in the side of the unit.
2. The unit is connected via one of the cable
glands in the upper or lower side of the
unit.
Different combinations for controlling fan
speed are available. See wiring diagram (p. 6).
Water coil connection
The water coil has copper tubes with
aluminium fins and is suitable for connection
to a closed water heating system. The heating
coil must not be connected to a mains
pressure water system or an open water
system.
The water pipes are connected to the
terminals with DN25 (1"), internal thread on
the inside of the unit. Use a wrench or similar
to hold the air curtain connections to prevent
straining the pipes and subsequent water
leakage during connection to water supply
pipe-work.
The connections to the heating coil must be
equipped with shut off valves to allow problem
free removal. The highest point of the pipes
supplying the unit with water must also be
fitted with a bleed valve. The installation must
be carried out by an authorised installer.
Basic setting fan speed
The fan speed is set using the speed control.
Note that the air flow direction and speed
may need fine adjustment depending on the
loading of the door.
Assembly and operating instructions
Содержание
- Thermozone sf wl 1
- Connections 3
- Electrical connections water connections 3
- Minimum mounting distance 3
- Mounting 3
- Positions of adjustable feet securing the unit to the door 3
- Accessories 4
- Mdc mdcdc included 4
- Rti2 cb30n 4
- Dn25 1 5
- Fh1025 5
- Thermozone sf 5
- Water regulators 5
- Wiring diagrams sf wl 6
- Output charts water 7
- Pressure drop bar 8
- Pressure drop kpa 8
- Pressure drop water 8
- The pressure drop is calculated for an average temperature of 70 c pvv 80 60 for other water temperatures the pressure drop is multiplied by the factor k 8
- Water flow 8
- Water flow l s 8
- Water pressure drop over controls and valves 8
- Water pressure drop over sf wl water coil 8
- Aggregatet kan förlängas till max 3900 mm förlängning utan fläktar 9
- Applicable at water temperature 80 60 c air temperature 15 c 9
- Conditions distance to the unit 5 metres directional factor 2 equivalent absorption area 200 9
- Extension possible up to 3900 mm extension without fans 9
- Förhållanden avstånd till aggregat 5 meter riktningsfaktor 2 ekvivalent absorptionsarea 200 9
- Gäller vid vattentemperatur 80 60 c lufttemperatur in 15 c gb 9
- T temperature rise of passing air at maximum heat output and highest airflow 9
- T temperaturhöjning på genomgående luft vid maximal värmeeffekt och högsta luftflöde 9
- T увеличение температуры воздуха при максимальной мощности и полном расходе 9
- Technical specifications 9
- Thermozone sf wl 9
- Возможно удлинение без вентиляторов до 3900 мм 9
- Данные для температуры воды 80 60 c и воздуха на входе 15 c 9
- Условия расстояние до завесы 5 метров фактор направленности 2 эквивалентная площадь звукопоглощения 200 9
- Montage och bruksanvisning 10
- Vattenreglering 12
- Assembly and operating instructions 13
- Water control 15
- Инструкция по монтажу и эксплуатации 16
- Управление расходом теплоносителя 18
- Instrukcja montażu i obsługi 19
- Regulacja przepływu wody 21
Похожие устройства
- Frico sf18e09 Инструкция по эксплуатации
- Frico ps215e14 Инструкция по эксплуатации
- Frico ps215e09 Инструкция по эксплуатации
- Frico ps210e09 Инструкция по эксплуатации
- Frico ps210e06 Инструкция по эксплуатации
- Frico ps210e03 Инструкция по эксплуатации
- Frico ar220w Инструкция по эксплуатации
- Frico ar220e18 Инструкция по эксплуатации
- Frico ar215w Инструкция по эксплуатации
- Frico ar215e11 Инструкция по эксплуатации
- Frico ar210w Инструкция по эксплуатации
- Frico ar210e09 Инструкция по эксплуатации
- Frico ad220w Инструкция по эксплуатации
- Frico ad215w Инструкция по эксплуатации
- Frico ad210w Инструкция по эксплуатации
- Frico swh33 Инструкция по эксплуатации
- Frico swh32 Инструкция по эксплуатации
- Frico swh22 Инструкция по эксплуатации
- Frico swh12 Инструкция по эксплуатации
- Frico swh02 Инструкция по эксплуатации