Frico swh22 Инструкция по эксплуатации онлайн [24/56] 193074
![Frico swh22 Инструкция по эксплуатации онлайн [24/56] 193074](/views2/1230829/page24/bg18.png)
SWH
24
GB
the filter is slid down behind the coil in tracks
for this purpose. The filter can be reached for
installation and cleaning/maintenance from
both top or bottom of the unit.
SWH with the extra air director SWLR
The extra air director is mounted to the unit
by hooking it onto the existing air director.
Ceiling mounting
The unit, the mixing cabinet and the filter
section are mounted onto each other on the
floor and lifted up as one unit to be mounted
on the ceiling. The units should be mounted
together with screws or guides.
Connection of heating coil
The installation should be carried out by a
certified installer. By turning the fan heater,
pipe connections are possible on both sides.
Heating coil with copper pipes. Smooth pipe
connections for soldering or compression
fittings. For correct inlet and outlet
connection of the heating coil, see dimension
sketch.
Note! Be careful while connecting the pipes to
prevent pipe damage and water leakage.
The heating coil must not be connected to
a mains pressure water system or an open
water system.
Prior to use, the pipe system should be
ventilated. The air valve should
be connected on a high point in the pipe
system. Air and draining valves are not
included in the heating coil.
Units that are likely to be exposed to air
temperatures below zero, for example when
a mixing cabinet is used, should be equipped
with external frost protection to ensure that
the heating coil is not damaged by frost.
Electrical installation
The electrical installation should be carried
out by a qualified electrician in conformity
with prevailing regulations. The appliance
should be preceded by an triple-pole switch
with at least 3 mm breaking gap.
The fan motor is connected via the
integrated control card that is located on the
unit.
The control system is preinstalledin the fan
heater with an integrated control card. SIRe is
supplied pre-programmed with quick-release
connections.See manual for SIRe.
The motor has a built-in thermal safety cut-
out to protect against overheating. Alarm goes
off and resets with SIRe. See manual for SIRe.
After the electrical installation of the motor,
check the rotation of the fan. Seen from the
inlet side, the impellers should be rotating
anti-clockwise.
Start-up
Note! When using for the first time or when
starting up after a long period of disuse, a
small amount of smoke and a slight odour
may occur temporarily, which is completely
normal.
Maintenance
To ensure performance and reliabilty of
the unit, inspection and cleaning should be
carried out reguarly. Inspection should be
carried out at least twice a year. Clean the
unit when needed. During inspection the
power supply must always be disconnected.
Cleaning the fan
Cleaning intervals of the fan is due to filter
(if any) and air quality. When a filter section
with a deep-pleated bag filter is used and the
indoor air is of normal quality, the unit is
generally cleaned once a year. If the impellers
are not cleanded properly, vibrations/noise
can occur and severly damage the bearings.
If the vibrations/noise remain after cleaning,
please contact a certified technician.
The unit, the mixing cabinet, the filter section
and the heating coil can be vaccumed from
dust.
When there are no accessories on the inlet
side, inspection of the fan can be made from
the outside of the unit. When the filter section
is used, inspection can be carried out by
the inspection door on the side of the filter
section. To inspect the fan when the mixing
cabinet is used (with no other accessories
on the inlet side), the mixing box must be
dismantled.
Содержание
- Accessories 2
- Fan heater swh 2
- Dimensions 3
- 09 21 kit for recessed installation 4
- 09 22 external room temperature sensor 4
- 09 23 modular cable rj12 3 m 4
- 09 24 modular cable rj12 5 m 4
- 09 25 modular cable rj12 10 m 4
- 09 26 modular cable rj12 15 m 4
- 09 27 modular cable rj11 3 m 4
- 09 28 modular cable rj11 5 m 4
- 09 29 modular cable rj11 10 m 4
- 09 30 modular cable rj11 15 m 4
- 09 57 49 306 01 control system sire basic 4
- 09 59 49 306 03 control system sire competent 4
- 09 61 49 306 05 control system sire advanced 4
- 09 63 49 306 08 control system sire advanced with mixing cabinett 4
- Clamp on sensor 4
- Control swh 4
- Sirecc403 4
- Sirecc405 4
- Sirecc410 4
- Sirecc415 4
- Sirecc603 4
- Sirecc605 4
- Sirecc610 4
- Sirecc615 4
- Sirecj4 4
- Sirecj6 4
- Sirefa 4
- Sirefaw 4
- Sirefc 4
- Sirertx 4
- Sireur 4
- Sirewta 4
- Type rsk nr el nr description l m 4
- Used to join two rj11 4 4 4
- Used to join two rj12 6 6 4
- Type rsk nr description flow voltage v connection kvs 5
- Vmo15lf 5
- Vmo15nf 5
- Vmop15lf 5
- Vmop15n 5
- Vmop20 5
- Vmop25 5
- Vos15lf 5
- Vos15nf 5
- Vosp15lf 5
- Vosp15nf 5
- Vosp20 5
- Vosp25 5
- Water regulation 5
- Actuator 230v 6
- Black blue 6
- C1 c2 room 6
- F1 f2 f3 f5 f4 n l n h1 n h2 motor trafo heating 6
- Orange 6
- Pe l n 6
- Supply 230v 6
- Tbtb z1u2u1 z2 pe 6
- White black blue 6
- Wiring diagrams swh 6
- Yellow 6
- Yellow green 6
- Parallell connection 7
- Sire basic 7
- Sireb1 7
- Siresd230 7
- Siresd230 sirertx optional sireub1 7
- Siresd230 sirertx optional sireub1 sireb1 internal 7
- Wiring diagrams swh 7
- Sire competent 8
- Sirec1x 8
- Sirertx optional 8
- Siresd230 8
- Sireua1 8
- Sire advanced 9
- Sirea1x 9
- Sireb1 9
- Sireotx 9
- Sirertx optional 9
- Siresdm24 9
- Sirest23024 9
- Sireua1 9
- Sirewta optional 9
- Sire advanced with mixing cabinet 10
- Sirea1x 10
- Sireb1 10
- Sireotx 10
- Sirertx optional 10
- Siresdm24 10
- Siresmm24 10
- Sirest23024 10
- Sireua1 10
- Sirewta return water temp sensor 10
- Air temp out c 12
- Incoming outgoing water temperature 130 70 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 12
- Output charts water 12
- Output kw 12
- Pressure drop kpa 12
- Pressure drop kpa swh02 12
- Water flow l s 12
- Air temp out c 13
- Incoming outgoing water temperature 110 80 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 13
- Output charts water 13
- Output kw 13
- Pressure drop kpa 13
- Pressure drop kpa swh02 13
- Water flow l s 13
- Air temp out c 14
- Incoming outgoing water temperature 90 70 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 14
- Output charts water 14
- Output kw 14
- Pressure drop kpa 14
- Pressure drop kpa swh02 14
- Water flow l s 14
- Air temp out c 15
- Incoming outgoing water temperature 80 60 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 15
- Output charts water 15
- Output kw 15
- Pressure drop kpa 15
- Pressure drop kpa swh02 15
- Water flow l s 15
- Air temp out c 16
- Incoming outgoing water temperature 60 50 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 16
- Output kw 16
- Pressure drop kpa 16
- Pressure drop kpa swh02 16
- Water flow l s 16
- Air temp out c 17
- Incoming outgoing water temperature 60 40 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 17
- Output kw 17
- Pressure drop kpa 17
- Pressure drop kpa swh02 17
- Water flow l s 17
- Air temp out c 18
- Incoming outgoing water temperature 60 30 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 18
- Output kw 18
- Pressure drop kpa 18
- Pressure drop kpa swh02 18
- Water flow l s 18
- Air temp out c 19
- Incoming outgoing water temperature 55 35 c air temp in 15 c air temp in 0 c air temp in 15 c type fan position airflow m³ s 19
- Output kw 19
- Pressure drop kpa 19
- Pressure drop kpa swh02 19
- Water flow l s 19
- Montage och bruksanvisning 20
- Assembly and operating instructions 23
- Monterings og bruksanvisning 26
- Asennus ja käyttöohje 29
- Montage und betriebsanleitung 32
- Consignes de montage et mode d emploi 36
- Montage och bruksanvisning 39
- Инструкция по установке и эксплуатации 42
- Мотор вентилятора мотор вентилятора не требует специального обслуживания если уровень шума или вибрации начинает повышаться необходимо установить причину неполадки при необходимости заменить подшипники замена подшипников должна производиться квалифицированным персоналом 45
- Instrucciones de instalación y funcionamiento 46
- Montage en bedieningsinstructies 49
- Istruzioni operative e di installazione 52
Похожие устройства
- Frico swh12 Инструкция по эксплуатации
- Frico swh02 Инструкция по эксплуатации
- Frico swh02 Инструкция по эксплуатации
- Frico pa4210e12 Инструкция по эксплуатации
- Frico pa4215e18 Инструкция по эксплуатации
- Frico pa4220e24 Инструкция по эксплуатации
- Frico pa4225e30 Инструкция по эксплуатации
- Frico ar320e18 Инструкция по эксплуатации
- Frico ar315e14 Инструкция по эксплуатации
- Frico ar310w Инструкция по эксплуатации
- Frico ar310e09 Инструкция по эксплуатации
- Frico p3510e08 Инструкция по эксплуатации
- Frico ad410w3 Инструкция по эксплуатации
- Frico ad420e27 Инструкция по эксплуатации
- Frico ad415e20 Инструкция по эксплуатации
- Frico ad410e14 Инструкция по эксплуатации
- Frico ad320w Инструкция по эксплуатации
- Frico ad315w Инструкция по эксплуатации
- Frico ad310w Инструкция по эксплуатации
- Frico ad320e18 Инструкция по эксплуатации