Hyundai H-DEH2-20L-UI008 [7/44] Condensate removal

Hyundai H-DEH2-20L-UI008 [7/44] Condensate removal
7.
Dehumidier
EN
Condensate removal
In the course of air drying, the appliance shall accumulate the condensate (water recovered
from air). As soon as the condensate tank is full, the TANK FULL indicator will ash on and the
appliance will stop working. In order to resume working it is necessary to remove the tank and
pour water (see a scheme below).
The appliance may also work in constant mode without the necessity of occasional pouring of
water from the tank. For that the user should insert a special drainage hose (not included in
the delivery set) into a special aperture for constant condensate removal and direct water to a
prepared tank or drainage system (see a scheme).
Fig. 3 Fig. 4
NOTE:
1. If the moisture level in the room is 3% lower than the one set by
the user, the compressor will stop working. As soon as air moisture
level exceeds the set one by 3%, the compressor wick start working
again.
2. If the Tank Full indicator is ashing on, it is necessary to pour water
from the tank.
3. The drier will stop working, if the set moisture level is higher than
the current air moisture level in the room.
4. Range of operating temperatures for this appliance is 5-32°С
5. If the drier does not work (the Power indicator does not ash on) or
if the appliance makes long pauses in its work, wait for 10 minutes
and then try to turn it on again. If the appliance will not resume
working, refer to a shop assistant or to a service center.
6. If the appliance is turned o, it can be turned on only in 3 minutes.
The view is to protect the compressor from damaging.
7. If the Defrost indicator is ashing on, it means that the evaporator
has supercooled and needs automatic defrosting. In this mode
the compressor will stop working and the fan will continue its
operation.