www.timberk.com • gas heater
5
Ventilation
During operation, the gas-fired heater burns oxygen contained in air and
emits carbon dioxide (CO2).
It is important to remember that operation of the gas-fired ceramic heater is
permitted only in well ventilated rooms. This allows keeping the necessary
concentration of oxygen in air and removing combustion products.
Operation of the heater in closed and poorly ventilated rooms may create
The use of ceramic gas heater admissible if:
1. Gas heater installed on flat surfaces
2. Heat ceramic radiator heater is situated to the back of the gas bag and
is not directed at him
3. Gas hose conducted with rear heater
Always use only the gas type indicated by the manufacturer.
During operation of the appliance, watch that the gas cylinder is always
strictly vertical. Use of the cylinder in any other position may result in
occurrence of an emergency situation, breakdown of the appliance, and
infliction of a significant damage to you and/or your property.
It is prohibited to move or anyhow cover the heater during operation, as
well as after shutdown, if the heater is still hot.
The heater should be placed for operation so that its face plate is directed
towards the room center. At that, distances to walls or other objects on
sides and behind the appliance should be at least 1 m.
7. CONTROL OF CERAMIC GAS-FIRED HEATER
IMPORTANT!
All gas joints and pipes should be absolutely tight to
exclude even slightest gas leaks. Never use matches,
lighters, and other sources of open flame for leak checks
of joints. Use soapy water.
It is prohibited to use the gas-fired heater in flats of high-
rise buildings, bedrooms, bathrooms, and cellars.
Upon first ignition, it is recommended to preliminarily
switch the heater on outdoors, after which it can be
used indoors. The room, where the gas-fired heater is
used, should be equipped with natural ventilation.
Do not use the heater during sleep.
Always use only certified, recommended by the
manufacturer, and properly rated hoses/pressure
reducers for connection of the appliance.
IMPORTANT!
Do not start the gas-fired ceramic heater in rooms
having volume less than 84 m3.
The minimum area of a vent should be at least 105 cm2.
Necessary air exchange 10m3 / hour der 1 kW of
thermal power heater.
IMPORTANT!
Never use a gas ceramic heater without attached
supporting legs
an asphyxiating atmosphere and cause a lack of oxygen. If the oxygen
concentration decreases below 18%, the ODS system (oxygen detector)
activates and switches the heater off. In this case it is necessary to ventilate
the room before restarting the heating mode.