I I I I Emergency control shall be used if the remote control board is lost or broken or batteries are low Using an emergency control button situated on the indoor unit control panel you may select COOL or AUTO mode of the conditioner work Pressing this button select a mode of the conditioner work AUTO COOL the conditioner is OFF AUTO again etc Figure 3 Description of the remote control board I I I 21 Button AIR FLOW Using this button you may turn the blind swinging on and off 22 Button TIMER Using this button you may set the time for turning the conditioner on and off from 1 to 24 hours If the conditioner is off you may set the timefor automatic turning on in a set time interval And viceversa if the conditioner is on you may set the time for automatic turning off 23 Button SLEEP Using this button you may turn the sleep mode on and off In this mode thefan speed will be low 24 Button TURBO Using this button you may turn the turbo mode on and off In this mode the conditioner shows the maximum cooling in cool mode or heating in heat mode capacity This mode cannot be used in modes Auto Dry Fan 25 Button HOLD Using this button you may lock all other buttons of the control board including the button on indoor unit control panel To unlock this mode you should press this button once more 26 Button CLEAN This button is not used forthis series of conditioners 27 Button LAMP This button is not used forthis series of conditioners Indication of the control board display shall correspond to selected modes Work with remote control board Mounting and replacement of batteries mount two LR03 batteries according to polarity indicated on the remote control board 16 Select mode button MODE Using this button you may select a required mode Auto Cool Dry Heat Fan 17 Button TEMP decrease increase for setting of the required air temperature from 16 to 32 C Using this button you may set the required air temperature indoors 18 Button ON OFF Using this button you may turn the conditioner on or off 19 Button FAN SPEED Using this button you may select rotation speed of the indoor unitfan Auto High Middle Low In Auto mode the fan speed will change automatically In dry mode the fan speed will remain unchanged Low 20 Button SWING Using this button you may regulate position of air relief blinds and forward treated air to various directions alkaline In order to avoid malfunction of the remote control board do not insert used batteries or batteries of various types If the conditioner is not used for a long time remove batteries from the board or else electrolyte may leak and damage the board In normal operation of the conditioner average service life of batteries will be about a half year Replace batteries if command receiving is not confirmed with an audio signal or if the display does not show a sign of command transfer When generating commands from the remote control board point an IRradiator on a remote control signal receiver situated on the indoor unit Hold the remote control board at the distance of no more than 8 m from the indoor unit

Скачать
Случайные обсуждения