Hyundai H-AR7-18H-UI137 [24/68] Normal function of the air conditioner

Hyundai H-AR7-12H-UI136 [24/68] Normal function of the air conditioner
24.
Electric air conditioner (split system)
EN
be set too small,in case the condensed water forms and drops from the horizontal louver.
Press the AUTO/COOL button under the front panel and the open angle of the horizontal
louver will be restored to the standard angle when the condensed water forms on the
horizontal louver.
11. Special function display
Displays the special functions in the following ways(for some models only):
Displays for three seconds when Timer ON, Fresh, Swing, Turbo or Silence feature is activated.
Displays for three seconds when Timer OFF is set.
Displays for three seconds when Fresh, Swing, Turbo or Silence feature is cancelled.
Displays under defrosting operation.
Displays when anti-cold air feature is activated under heating mode.
Displays during self clean operation(if applicable).
Displays under 8OC heating operation(if applicable).
Normal function of the air conditioner
Stop the air conditioner immediately if one of the following faults occur. Disconnect the power
and contact the nearest customer service center.
Trouble
OPERATION/RUN indicator or other indicators continue ashing and
this ash can’t be xed by disconnecting the power, and then connect it in again.
Fuse blows frequently or circuit breaker trips frequently.
Other objects or water penetrate the air conditioner.
The remote controller won’t work or works abnormally.
If one of the following code appears on the display area:
E0,E1,E2,E3.....or P0,P1,P2,P3......
Malfunctions Cause What should be done?
Unit does not start
Power cut Wait for power to be restored.
Unit may have become un-
plugged.
Check that plug is securely in wall
receptacle.
Fuse may have blown. Replace the fuse.
Battery in Remote controller
may have been exhausted.
Replace the battery.
The time you have set with timer
is incorrect.
Wait or cancel timer setting.

Содержание