Hyundai H-AR1-12H-UI012 [12/52] Sleep mode

Hyundai H-AR1-18H-UI013 [12/52] Sleep mode
12.
Electric air conditioner (split system)
EN
TIMER mode
Procedure of timing:
– If the conditioner is o, then press the «TIMER» button to activate the automatic turning on.
Pressing this button once again, set the time for turning the conditioner on in the set time
interval. To cancel the timer mode, press the «TIMER» button once again.
–If the conditioner is working, then press the «TIMER» button to activate the automatic turning
o. Pressing this button once again, set the time for turning the conditioner o in the set time
interval. To cancel the timer mode, press the «TIMER» button once again.
«SLEEP» mode
Button «SLEEP» (Night Care). Press this button to increase (in the cooling mode) or decrease (in
the heating mode) the air conditioner temperature in relation to the set value by 1°C per hour
for 2 hours aer the pressing. The air conditioner will be switched o aer 5 hours of operation
in this mode.
This mode allows energy saving and creates comfortable conditions at night.
Regulation of treated air ow direction
Regulating the position of deectors (blinds), set the direction of treated air ow ensuring
uniform distribution of temperature and the most comfort conditions in the room. To change the
position of deectors, use the «SWING» button.
8. MAINTENANCE
Before cleaning unplug the conditioner.
Cleaning of the indoor unit and remote control board:
Indoor unit and remote control board should be cleaned with a dry so cloth.
If the indoor unit is too unclean, moisten the cloth with cold water.
It is prohibited to clean the remote control board with moist cloth.
In order to avoid the damage of paint or details of the conditioner, do not clean it with brushes
and do not leave them on the surface of indoor unit.
In order to avoid the damage of surface or deformation of the conditioner details, do not clean
it with petrol, solvents, cleaning powders or other chemically active substances.
Before a sustained interruption in the conditioner work:
Turn the conditioner on for several hours in the FAN mode. It will allow you to dry its inner
cavities
Unplug the conditioner. Remove the batteries from the remote control board. Checks before
starting:
Make sure that an air lter is installed.
Make sure that air inlet and outlet grilles of the outdoor unit are not blocked by foreign objects.
Cleaning of air lter
Air lter cleans the air entering the conditioner from dust and foreign particles. If the lter is
contaminated, the conditioner capacity decreases sharply.
If the conditioner is operated permanently, the lter should be cleaned once per two weeks.
If the conditioner is installed in a room with dusty atmosphere, then the air lter should be
cleaned more oen.
To remove the lter, open the indoor unit panel.
Remove air lters. Clean the lter with a vacuum cleaner or rinse it in clean water. If the lter is
contaminated heavily, clean it with a so brush and wash in diluted washing solution, then dry
it in a cool place.
While cleaning the lter with the vacuum cleaner, hold it with contaminated surface up. While
washing the lter in water, hold it with contaminated surface down.
Do not dry the lter in the sun or near a re.
Set the air lter to initial position and close the panel.