SinePower Connecting the inverter
21
!
Install a residual current circuit breaker in the socket distribution circuit.
9.6 Setting the earthing bridge (fig. 7 8, page 5)
(MSI1800T only)
Remove the earthing screw from the top hole.
Screw the screw into the bottom hole.
9.7 Connecting the MCR-7 or MCR-9 remote control
(accessory)
A
Connect the remote control (accessory) to the remote port (fig. 5 2, page 4).
WARNING! Danger of electrocution!
If you wish to connect more than one appliance to the inverter and install
a socket distribution circuit, you must arrange a circuit breaker (residual
current circuit breaker) and set a grounding bridge in the inverter.
NOTICE!
Only plug in the connection to the remote control in the remote port.
The device can be damaged by connecting it incorrectly.
Ensure that the remote control and inverter are supplied with the
same input voltage.
Follow the instruction manual of the remote control.