Sven OVP-11F [21/22] Voltage relay

Sven OVP-11F [21/22] Voltage relay
ENG
Voltage Relay
20
The relay enters the turn-on delay mode after its connection to the power
supply network or when it leaves the protection mode. In this mode the
equipment connected to the relay remains de-energized till the end of delay
time, and the indicator a blinks during this time. The turn-on delay value for
OVP-11F voltage relay is180 sec.
Force transition from the turn-on delay mode to the operation mode can be
done by pressing the button d.
Parameters
Rated voltage, V
Maximum load current, А
Maximum power, kVА
Protection actuation time
Operation threshold to decrease power
supply voltage, V
Operation threshold to increase power
supply voltage, V
Turn-on delay time, sec
Dimensions, mm
Value
~220
15
3.3
not more than 0.3 sec
185 ± 3 %
255 ± 3 %
180
54 × 120 × 80
Notes:
Technical specications given in this table are supplemental infor-
mation and cannot give occasion to claims.
Technical specications and package contents are subject to chan-
ge without notice due to the improvement of SVEN production.
9.
TECHNICAL SPECIFICATIONS