Cyberpower V 800E — руководство по эксплуатации и обслуживанию источника бесперебойного питания [2/4]

Cyberpower V 800E [2/4] The serial cable is not the cable that was provided with the unit
FUNCTIONAL TEST
AC Mode
The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also
regulates the output voltage to within a narrow range.
On-Battery Mode
The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local
users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to
the load from the battery and through its inverter and the output voltage and frequency of the UPS are
regulated within a narrow range
1. Switch On
Press the power switch on the front panel then the status LCD will light up.
2. Switch Off
Press again the power switch, the status LCD on the front panel will go off.
3. Cold Start / Start on Battery:
This UPS can be turned on even when AC is not present.
Press the power switch on the front panel then the status LCD will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1. Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that
contains alcoholic ingredient.
2. The expected lifetime of the battery is around 3 years. Improper operation and harsh environment
will reduce the actual lifetime.
3. Unplug the UPS from power inlet if the UPS will not operate for long period of time.
STORAGE
1. First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables
connected the UPS to avoid battery drain.
2. The UPS should be stored in a cool dry location.
3. Make sure the battery is fully charged before the UPS is stored.
4. For extended storage in moderate climates, the battery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat
it every 2 months in high temperature locations.
TROUBLE SHOOTING
Problem Possible Cause Solution
The UPS does
not perform
expected
runtime.
Batteries are not fully
charged.
Recharge the battery by leaving the UPS
plugged in.
Battery is slightly worn out.
Contact CyberPower Systems at
support@cpsww.eu
The UPS will not
turn on.
The unit is not connected to
an AC outlet.
The unit must be connected to a
220-240V 50/60Hz outlet.
The battery is worn out.
Contact CyberPower Systems at
support@cpsww.eu
Mechanical problem.
Contact CyberPower Systems at
support@cpsww.eu
Outlets do not
provide power to
equipment
Circuit breaker is tripped
due to overload
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the
circuit breaker knob.
Batteries are discharged
Allow the unit to recharge for at least 4
hours.
Unit has been damaged by
a surge or spike.
Contact CyberPower Systems at
support@cpsww.eu
PowerPanel®
Personal Edition
is inactive (all
icons are gray).
The serial/USB cable is not
connected.
Connect the serial/USB cable to the UPS
unit and an open serial port on the back
of the computer. You must use the cable
that came with the unit.
The serial/USB cable is
connected to the wrong
port.
Try another serial/USB port of your
computer.
The unit is not providing
battery power.
Shutdown your computer and turn the
UPS off. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
The serial cable is not the
cable that was provided with
the unit.
You must use the cable included with the
unit for the software.
TECHNICAL SPECIFICATIONS
Model Value 600ELCD Value 800ELCD Value 1000ELCD
Capacity (VA) 600VA 800VA 1000VA
Capacity (W atts) 360W 480W 550W
Input
Frequency Range 47~63Hz(Auto Sensing)
Output
On Battery Output
Voltage
Simulated Sine Wave at 230Vac +/-10%
On Battery Output
Frequency
50/60 Hz
Overload Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Total # of UPS
Receptacles
(2) Schuko
Maximum Dimensions 32cm(L)*10cm(W)*14cm(H)
Weight 5.2 kg 5.8 kg 6.1 kg
Battery
Sealed Maintenance
Free Lead Acid Battery
12V/7AH 12V / 9AH 12V / 9AH
Typical Recharge Time 8 Hours
Warning Diagnostics
Indicators Power On, UPS Status Display, Capacity Display, Digital Value
Display
Audible Alarms On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature +32qF to 104qF ( 0qC to 40qC )
Operating Relative
Humidity
0 to 95% NON-CONDENSING
Communication
PowerPanel
®
Personal Edition
Software
Windows 98/ME/2000/NT/XP/Vista/7
Management
Auto-Charger Yes
Auto-Restart Yes
USB Yes
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
Select SW
Press
UPS Status Display Capacity Display Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Ti me
%
of Load
%
of Batt.
Initial V X -- X V X V
1st VX--X V X V
2nd V X -- X V X V
3rd VX--X X V V
4th VX--X V X V
5th(Return) V X -- X V X V
Press >3sec
(Sound Disable)
VXVX -- -- -- -- -- -- --
Press >3sec
again
(Sound Ena ble)
VXXX -- -- -- -- -- -- --
(Overload) V X -- V -- -- -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Battery mode
Select SW
Press
UPS Status Display Capacity Display Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Ti me
%
of Load
%
of Batt.
Initial X V -- X X V V
1st XV--X X V V
2nd X V -- X V X V
3rd XV--X X V V
4th XV--X X V V
5th(Return) X V -- X X V V
Press >3sec
(Sound Disable)
XVVX -- -- -- -- -- -- --
Press >3sec
again
(Sound Ena ble)
XVXX -- -- -- -- -- -- --
(Overload) X V -- V -- -- -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Visit www.cpsww.eu for more product information and the nearest CyberPower local contact for your
region.
Entire contents copyright ©2011 CyberPower Systems, Inc All rights reserved. Reproduction
in whole or in part without permission is prohibited.

Содержание

Узнайте, как правильно использовать и обслуживать источник бесперебойного питания. Подробные инструкции по включению, обслуживанию и устранению неполадок.

Скачать