Timberk AC TIM 18H S10B [10/36] Maintenance

Timberk AC TIM 07H S10B [10/36] Maintenance
www.timberk.com • Electric air conditioner
10
8. MAINTENANCE
• Beforecleaningunplugtheconditioner.
• Cleaningoftheindoorunitandremotecontrolboard:
• Indoorunitandremotecontrolboardshouldbecleanedwithadrysoftcloth.
• Iftheindoorunitistoounclean,moistentheclothwithcoldwater.
• Itisprohibitedtocleantheremotecontrolboardwithmoistcloth.
• Inordertoavoidthedamageofpaintordetailsoftheconditioner,donot
cleanitwithbrushesanddonotleavethemonthesurfaceofindoorunit.
• Inordertoavoidthedamageofsurface ordeformationoftheconditioner
details, do not clean it with petrol, solvents, cleaning powders or other
chemicallyactivesubstances.
• Beforeasustainedinterruptionintheconditionerwork:
• TurntheconditioneronforseveralhoursintheFANmode.Itwillallowyou
todryitsinnercavities
• Unplugtheconditioner.Removethebatteriesfromtheremotecontrolboard.
Checksbeforestarting:
• Makesurethatanairfilterisinstalled.
• Makesurethatairinletandoutletgrillesoftheoutdoorunitarenotblocked
byforeignobjects.
• Cleaningofairfilter
• Airfiltercleanstheairenteringtheconditionerfromdustandforeignparticles.
Ifthefilteriscontaminated,theconditionercapacitydecreasessharply.
• Iftheconditionerisoperatedpermanently,thefiltershouldbecleanedonce
pertwoweeks.
• Iftheconditionerisinstalledinaroomwithdustyatmosphere,thentheair
filtershouldbecleanedmoreoften.
• To remove the filter, open the indoor unit panel.
• Remove air filters. Clean the filter with a vacuum cleaner or rinse it in
clean water. If the filter is contaminated heavily, clean it with a soft brush and
wash in diluted washing solution, then dry it in a cool place.
• Whilecleaningthefilterwiththevacuumcleaner,holditwithcontaminated
surfaceup.Whilewashingthefilterinwater,holditwithcontaminatedsurface
down.
• Donotdrythefilterinthesunornearafire.
• Settheairfiltertoinitialpositionandclosethepanel.
9. TROUBLESHOOTING
Failuresandtheirpossiblereasons:
Failure Possible reason Actions
The conditioner does
not work
Interruptions in power supply
Wait for restoration of power
supply
Batteries in the remote control
board are low
Replace the batteries
Time of tuming on is set by
the timer
Wait till the conditooner turns
on by the timer or cancel the
timer setting
Insufficient cooling or
heating capacity
The set air temperature is too
high or too low
Set the air temperature
correctly
The air filter is clogged with dust Clean the air filter
Foreign objects block the air intel
and retum air grillages of the
outdoor unit
Remove foreign objects
The conditioner works,
but does not cool or
heat the room
A three-minute delay of
compressor tuming on
Wait a little
The air temperature is set
incorrectly
Set the temperature correctly

Содержание

Скачать