Denyo TLG-7.5LSK 60Hz [4/4] Generators
![Denyo TLG-15LSX [4/4] Generators](/views2/1308506/page4/bg4.png)
REVOLUTION
Generators
―
T
HREE PHASE TYPE
―
TLG-13LSY・18LSY
❶
Circuit Breaker(Three Phase Output)
❷
Circuit Breaker(Output
Socket)
❸
Frequency Meter
❹
AC Ammeter
❺
AC Voltmeter
❻
Engine Monitor
❼
Starter Switch
❽
Voltage Regulater
❾
Earth
Leakage Relay
Adjustable Speed Lever
Adjustable Frequency
Screw
Single-phase Output Socket(2×15A)
Ground
Terminal(For Bonnet)
Three Phase Output Terminals
Eco-Friendly / Eco- Conscious Series
(
Models
)
Extremely Quiet Operation: 68dB(A) or less.
This high-speed system operates at low noise
levels that will not disturb the human environment.
This has been achieved by using highly effective
sound-insulating materials and a unique duct
construction, which is a part of the advanced
cooling system developed by Denyo.
Use of Clean Engines
The used in these generators meet the Californian
Atmospheric Pollution Regulation, which is one of
the world’s most stringent anti-pollution standards.
This is achieved by these engines using a PCV
(Purge Control Valve) system. Therefore, these
engines do not discharge blow-by gas to the
outside, which keeps the interior of the machine
cleaner and exhaust emissions are minimized.
Additional Features
50Hz / 60Hz Operation
You can operate the TLG Series at both 50Hz and 60Hz
by simply adjusting the engine speed using the throttle
control knob on the control panel.
Compact Design
The compact and stackable design of the TLG Series
facilitates the most effective use of storage space. All the
machines are equipped with a balanced, centered lifting
lug (hook) to further enhance generator’s portability.
Emergency Shut-Down Devices
To protect the generator from malfunctions, a warning
lamp and an in-built emergency system are standard
specification to detect the low oil pressure, high water
temperature, and failure of charging. If these
abnormalities are detected, the warning lamp will light up
and the engine will come to an emergency stop. There is
also a circuit breaker to shutdown immediately in the
case of AC overload.
Optional Earth Leakage Relay
To prevent electric shock, it is recommended that these
generators are equipped with leakage detectors and a
relay circuit breaker.
TLG-13LSY
TLG-7.5LSK
TLG-18LSY
❶
❷
❸❹❺ ❻
❼
❾
❽
Содержание
Похожие устройства
- Denyo DA-3000SS Инструкция по эксплуатации
- Denyo DA-6000 SS Инструкция по эксплуатации
- Denyo TLG-12ESX Инструкция по эксплуатации
- Denyo TLG-13SPY Инструкция по эксплуатации
- Denyo TLG 15 ESX Инструкция по эксплуатации
- Denyo TLG 18LSY Инструкция по эксплуатации
- Denyo TLG-7.5SPK Инструкция по эксплуатации
- Denyo DCA-100USI Инструкция по эксплуатации
- Denyo DCA-100USI 60Hz Инструкция по эксплуатации
- Denyo DCA 125USH Инструкция по эксплуатации
- Denyo DCA 125USH 60Hz Инструкция по эксплуатации
- Denyo DCA 150USK Инструкция по эксплуатации
- Denyo DCA 150USK 60Hz Инструкция по эксплуатации
- Denyo DCA-25USI2 Инструкция по эксплуатации
- Denyo DCA-25USI2 60Hz Инструкция по эксплуатации
- Denyo DCA 45USI2 Инструкция по эксплуатации
- Denyo DCA 45USI2 60Hz Инструкция по эксплуатации
- Denyo DCA-60USH2 Инструкция по эксплуатации
- Denyo DCA-60USH2 60Hz Инструкция по эксплуатации
- Denyo DAW-180SS Инструкция по эксплуатации