Toshiba RAS-13N3KV-E / RAS-13N3AV-E [4/7] Maintenance
![Toshiba RAS-22N3KV-E/RAS-22N3AV-E [4/7] Maintenance](/views2/1310312/page4/bg4.png)
Set your preferred operation for future use. The setting will be memorized by the
unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The P mark displays.
3. Press
: Operate the preset operation.
To automatically restart the air conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel
the operation. (3 beep sound but OPERATION lamp does not blink)
• In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
QUIET
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling due to low sound features.
For comfortable sleep, automatically control air fl ow and automatically turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before blowing warm air.
3. Warm air control: When the room temperature reaches the set temperature,
the fan speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into the room.
When the outdoor temperature is too low, use another recommended heating
apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit where
it will not be subjected to snow drifts, accumulation of leaves or other seasonal
debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of
plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times within
30 seconds.
Temp.
Operation
Outdoor Temperature
Room
Temperature
Heating
–15°C ~ 24°C
Less than 28°C
Cooling
–10°C ~ 46°C
21°C ~ 32°C
Dry
–10°C ~ 46°C
17°C ~ 32°C
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil.
“00” will be shown on the display.
4. Press
during pushing . “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from
factory is A.
The unit does not operate.
Cooling or Heating is abnormally low.
• The power main switch is turned
off.
• The circuit breaker is activated to
cut off the power supply.
• Stoppage of electric current.
• ON timer is set.
• The fi lters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or DRY.
OPERATION AND PERFORMANCE
19
TROUBLESHOOTING (CHECK POINT)
20
REMOTE CONTROL A-B SELECTION
21
PRESET OPERATION
13
AUTO RESTART OPERATION
14
QUIET OPERATION
15
COMFORT SLEEP OPERATION
16
MAINTENANCE
17
SELF CLEANING OPERATION (COOL AND
DRY OPERATION ONLY)
18
21
TSB 1110650192 (01_EN).indd 4TSB 1110650192 (01_EN).indd 4 08/06/12 2:59 PM08/06/12 2:59 PM
Содержание
- Air conditioner split type 1
- For general public use 1
- Indoor unit ras 13 18 22n3kv series 1
- Outdoor unit ras 13 18 22n3av series 1
- Owner s manual 1
- Caution 2
- Danger 2
- Indoor unit display 2
- Precautions for safety 2
- Warning 2
- Air flow direction 3
- Automatic operation 3
- Cooling heating fan only operation 3
- Dry operation 3
- Eco operation 3
- Hi power operation 3
- One touch 3
- Preparation before use 3
- Remote control 3
- Temporary operation 3
- Timer operation 3
- Auto restart operation 4
- Comfort sleep operation 4
- Maintenance 4
- Operation and performance 4
- Preset operation 4
- Quiet operation 4
- Remote control a b selection 4
- Self cleaning operation cool and dry operation only 4
- Troubleshooting check point 4
- Mepьi бeзoпachoctи 5
- Oпacho 5
- Tsb 1110650192 05_ru indd 14 tsb 1110650192 05_ru indd 14 08 06 12 3 01 pm 08 06 12 3 01 pm 5
- Диcплeй bhуtpehheгo блoкa 5
- Пpeдoctepeжehиe 5
- Пpeдупpeждehиe 5
- Abtomatичecкий peжиm 6
- Haпpabлehиe пotoкa boздухa 6
- Paбota b peжиmax темporary 6
- Paбota b peжиme cушки 6
- Paбota b peжиme eco 6
- Paбota b peжиme hi power 6
- Paбota b peжиme taйmepa 6
- Кнопка one touch 6
- Пoдгotobкa к иcпoльзobahию 6
- Пульт дистанционного управления 6
- Abtomatичecкий пobtophый пуcк 7
- Paбota b peжиme quiet бecшуmhый 7
- Paбota b peжиme пpeдbapиteльhых уctahoboк 7
- Peжиm camooчиctки toлькo b peжиmaх oхлaждehия и cушки 7
- Teхhичecкoe oбcлужиbahиe 7
- Выбор а в на пульте ду 7
- Уctpahehиe heпoлaдoк opиehtиpы 7
- Фуhкции и их иcпoлhehиe 7
Похожие устройства
- Toshiba RAS-13EKV-EE / RAS-13EAV-EE Инструкция по эксплуатации
- Toshiba RAS-07EKV-EE / RAS-07EAV-EE Инструкция по эксплуатации
- Toyota SLR4D Инструкция по эксплуатации
- Toyota ECO34C Инструкция по эксплуатации
- TransMount KRL300 для датчика эхолота, крепление на борт для лодки ПВХ Инструкция по эксплуатации
- TransMount TK-550 для датчика эхолота Инструкция по эксплуатации
- Transcend StoreJet 25M3, TS2TSJ25M3, 2ТБ, черный-зеленый Инструкция по эксплуатации
- Transcend JetFlash 710 Инструкция по эксплуатации
- Transcend JetFlash 710, 64ГБ Инструкция по эксплуатации
- Transcend JetFlash 820G, 64ГБ Инструкция по эксплуатации
- Transcend StoreJet 25H3, TS2TSJ25H3P, 2ТБ, фиолетовый-черный Инструкция по эксплуатации
- Transcend JetFlash 770, 16ГБ Инструкция по эксплуатации
- Transcend JetFlash 760 Инструкция по эксплуатации
- Tria HRL PREC BLOSSOM Инструкция по эксплуатации
- Tria HRL 4X TURQUOISE Инструкция по эксплуатации
- Tria HRL 4X GREEN Инструкция по эксплуатации
- Tripplite SMX2200XLRT2U Инструкция по эксплуатации
- Tristar KA-5283 Инструкция по эксплуатации
- TvHolder PLAZMA-EXE standart, напольная стойка для аппаратуры Инструкция по эксплуатации
- Ugears Механические 3D пазлы Грузовик UGM-11 Инструкция по эксплуатации