The information and instructions in this chap-
ter are for those who work on the machine:
the user, the maintenance engineer and also
non-specialised personnel.
All cleaning and maintenance operations
must be done after disconnecting the
power supply from the system.
7.1 ELEMENTARY SAFETY STAN-
DARDS
To carry out all the cleaning and servicing
operations in full safety.
we draw your attention to the following
safety standards.
- do not touch the machine with wet or
damp hands or feet.
- do not operate the machine with bare
feet.
- do not insert screwdrivers, kitchen uten-
sils or anything else between the guards
and the moving parts.
- before carrying out cleaning or servicing
operations, disconnect the machine from
the electricity mains, turn off at the
ON/OFF switch and remove the plug.
- do not pull the power lead to disconnect
the machine from the mains.
Removing protective and safety devices
must not be removed under any circum-
stances to carry out ordinary mainte-
nance operations. The manufacturer
declines all liability for accidents caused
through a failure to comply with this oblig-
ation.
Before starting up the machine it is nec-
essary to thoroughly clean the inside of
cell.
7.2 CONDENSER CLEANING
For the correct and efficient functioning of
the condenser, it is necessary for the air
condenser to be kept clean to allow the
free circulation of the air. This operation,
to be undertaken every thirty days at the
most can be performed with non-metallic
brushes in order to remove all the dust
and the down from the fins of the con-
denser itself.
You are advised to use a vacuum clean-
er in order not to spread removed dust
around the environment. If there are
greasy deposits, eliminate them with a
paint brush soaked in alcohol.
DO NOT SCRAPE THE SURFACES WITH
POINTED OR ABRASIVE BODIES.
THIS OPERATION MUST BE CARRIED
OUT WITH THE SYSTEM AT A STAND-
STILL.
CAUTION
The condenser has sharp edges.
While undertaking the abovementioned oper-
ations, always wear protective gloves, glass-
es and masks to protect the breathing appa-
ratus.
7. ORDINARY MAINTENANCE
C
C
A
A
U
U
T
T
I
I
O
O
N
N
!
!
!
!
!
!
THIS OPERATION MUST ONLY BE
CARRIED OUT BY A
LICENSED INSTALLATION ENGINEER.
Содержание
- Conservation cabinets 1
- Highcontrol 1
- Instructions for use 1
- General documentation 4
- General information 4
- Out fig for the stainless steel versions wear protective gloves when han dling the packaging and the wooden base 4
- Installation 5
- Accessories 8
- Hc 20 c nt ntv ntb btv fx 8
- Hc 20 nt 2 bt 2 btv 2 8
- Hc 40 btv ntb ntv 8
- Operating spaces 8
- Positioning 8
- Technical characteristics 9
- Date 12 04 03 time 11 54 23 11
- Hc20nt 2 hc20ntv hc20btv hc20btv 2 hc40ntv hc40btv 11
- Menu 2 change setpoint 11
- New set 15 c current 15 c 11
- Ok cell 21 c 11
- Call service 12
- Defrosting management 12
- F18 defr time s 19 02 02 06 09 12
- Menu 4 defrosting 12
- Ok cell 10 5 c 12
- Ok cell 18 c 12
- Al 27 high temp duration 015 13
- Al 27 high temp max temp 25 c 13
- Al 27 high temp s 18 03 02 12 29 13
- Alarm detected cell 24 0 c 13
- Ht cell 18 c 13
- Lt cell 24 c 13
- Management of the alarms detected and turning them off 13
- Al 26 black out b 15 03 02 10 22 14
- Al 26 black out max temp 12 c 14
- Al 26 black out s 15 03 02 10 01 14
- Alarm detected cell 24 0 c 14
- Button the cancellation is automatic when the mal function is rectified the alarm is however logged in the alarm menu 14
- Contact an authorised tecnomac centre in the case of a serious alarm 14
- Example of a blackout alarm 14
- Important 14
- In the case of high low temperature alarms before being registered a prealarm time of sixty minutes is calculated at the end of this time the controller logs the alarm in the alarm log and shows the following mask on the display 14
- Malfunctioning message they jeopardise machine operation call the service message display cause cancellation 14
- Serious alarm list serious alarms can determine the incorrect functioning of the conservator the display is the same as that described for the alarms and the signalling buzzer is acti vated to silence the buzzer press the 14
- To eliminate the indication go into the alarm log as shown in the paragraph above 14
- Alarm detected fixed logging of a remove the cause of the alarm alarm in the log and enter into menu 1 alarm log to reset the controller 15
- Ht fixed high temp prealarm automatic rectification 15
- List of any other malfunctions that cannot be signalled 15
- Lt fixed low temp prealarm automatic rectification 15
- Set clock loss of clock data set clock data 15
- Signalling messages they do not jeopardise the functioning of the machine message display cause cancellation 15
- Ordinary maintenance 16
Похожие устройства
- Castel MAC HC 20 NTB Инструкция по эксплуатации
- Steno PL7B Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Сертификат
- ТОРГМАШ УКМ-14 Каталог оборудования ТОРГМАШ
- Pavoni MINITEMPER Инструкция по эксплуатации
- Pavoni MINITEMPER Каталог оборудования Pavoni (англ.)
- Castel MAC HC 20 C Инструкция по эксплуатации
- Talsa Н26pa Инструкция по эксплуатации
- Talsa H42pas Инструкция по эксплуатации
- Talsa Н31pas Инструкция по эксплуатации
- Talsa Н15pa Инструкция по эксплуатации
- Helia Smoker 48 Инструкция по эксплуатации
- Helia Smoker 48 Рецепты копчения
- Helia Smoker 24 Инструкция по эксплуатации
- Helia Smoker 24 Рецепты копчения
- CAS CNW-460 Инструкция по эксплуатации
- CAS СNW-520 Инструкция по эксплуатации
- JEJU JDZ-260/PD Инструкция по эксплуатации
- JEJU JDZ-400/2E Инструкция по эксплуатации