BAR LINE (FRIMONT) BF 80 WS [2/2] Bf 80 as ws

BAR LINE (FRIMONT) BF 80 WS [2/2] Bf 80 as ws
626
mm
ORDERING AND SPECIFICATION INFORMATION
Air out-flow
o
f ICE Maker
A
ir
i
ntake
of
ICE
Maker
7
96/921 mm
BF 80 AS/WS
BF 80 AS/WS
BF 80 AS
Air 70 25 230/50/1 R 134a
R 134a
59
BF 80 WS
Water 73 25 230/50/1
ICE Production
per 24 hrs. at
10°C Air/10°C Water
Kgs. Refrigerant
2,2
16
Water
Consumption
Lt/60’
Max. Shipping
Weight
Kgs.
Model Cond. Bin Storage
Kgs.
Voltage
Characteristics
No.Unit .
60
51
Net Weight
Kgs.
52
7,5
7,5
Electric
Consumption
kwh/24h
Installation Note: allow 152 mm minimum space
at back for utility connections.
OPERATING LIMITS
Air Temp. Range 10°C - 40°C
W
ater Temp. Range 5°C - 35°C
W
ater Pressure Min. 1 bar
Max. 5 bar
Electrical Voltage 230V/50Hz/pH
(on selected models)
All units have stainless steel finish.
Refrigerant: R-134a
All specifications and performance data
are subject to normal manufacturing variances.
We reserve the right to make changes in design
and construction at any time without obligation.
ADV-Bar-Line 9/2010
5
29
m
m
BF 80
80 (3 1/8)
70 (2 3/4)
58 (2 1/4)
57 (2 1/4)
140 (5 1/2)
243 (9 9/16)
260 (10 1/4)
300 (11 13/16)
ø20 mm (13/16) OD-OVERFLOW DRAIN - OVERFLOW DRAIN
3/4 GAS WATER INLET - WATER COOLED ONLY
3/4 GAS WATER OUTLET - WATER COOLED ONLY
CORD SET
3/4” GAS WATER INLET
BAR-LINE Self Contained Machine - Criée Ice
Frimont S.p.A.
Via Lainate 31/b - 20010 Pogliano Milanese - (Milano) Italy
Tel. +39.02.93960.239 - Fax +39.02.93960.201
barline@frimont.it - www.barline.it

BF 80 AS WS 529 mm 796 921 mm Air intake of ICE Maker Air out flow of ICE Maker 626 mm OPERATING LIMITS BF 80 AS WS ater Temp Range 5 C 35 C ater Pressure Min 1 bar Max 5 bar W Electrical Voltage W 230V 50Hz pH on selected models All specifications and performance data are subject to normal manufacturing variances 70 2 3 4 10 C 40 C 58 2 1 4 Air Temp Range 80 3 1 8 BAR LINE Self Contained Machine Criée Ice BF 80 57 2 1 4 All units have stainless steel finish Refrigerant R 134a ø20 mm 13 16 OD OVERFLOW DRAIN OVERFLOW DRAIN 140 5 1 2 3 4 GAS WATER INLET WATER COOLED ONLY 243 9 9 16 3 4 GAS WATER OUTLET WATER COOLED ONLY 260 10 1 4 CORD SET 300 11 13 16 3 4 GAS WATER INLET Installation Note allow 152 mm minimum space at back for utility connections ORDERING AND SPECIFICATION INFORMATION Model No Cond Unit ICE Production per 24 hrs at 10 C Air 10 C Water Kgs Bin Storage Kgs Voltage Characteristics Refrigerant Water Consumption Lt 60 Electric Consumption kwh 24h Net Weight Kgs Max Shipping Weight Kgs BF 80 AS Air 70 25 230 50 1 R 134a 2 2 7 5 51 59 BF 80 WS Water 73 25 230 50 1 R 134a 16 7 5 52 60 We reserve the right to make changes in design and construction at any time without obligation ADV Bar Line 9 2010 Frimont S p A Via Lainate 31 b 20010 Pogliano Milanese Milano Italy Tel 39 02 93960 239 Fax 39 02 93960 201 barline frimont it www barline it

Скачать