Castel MAC E15-40 P Инструкция по эксплуатации онлайн [20/32] 272676

Castel MAC E15-40 P Инструкция по эксплуатации онлайн [20/32] 272676
GB
50
6
.11 USER ENTRY TO PROGRAMMING
DATA
Access for programming configuration para-
meters is only permitted when the appliance is
ON and there is no data memory error active.
Press and hold down push-buttons 7 and
8 at the same time for more than five sec-
onds; the computer will give access to the pro-
gramming function. Display 16 displays
PA, while display 15 will show the relative
value.
Use push-button 5 to select parame-
ter display (LED 5A illuminated), or display
16 with settings (LED 5B illuminated).
Use push-buttons 7 and 8 to scroll the
list of parameters (if LED 5A is illuminated)
or to modify the settings (if LED 5B is illu-
minated). The computer automatically exits
the programming function after approximately
40’.
6
.11 PRINTER (OPTIONAL)
- If you have to turn the instrument on/off press
- If you have to feed the paper by hand press
- If you have to change the roll of paper:
Turn the instrument off
Press for opening the panel at the front
of the instrument
Slip the roll of paper into the lower side of the
roller
Press as long as the roller drags the roll
of paper
Put the roll of paper into its box
Close the panel at the front of the instrument
- If you have to execute the print test
Switch off the power supply of the instrument
Press
Switch on the power supply of the instrument
- Signals: on/off led - if it is lighted, the instru-
ment will be in ON mode