Dimplex Bingham [10/16] Troubleshooting

Dimplex Bingham [10/16] Troubleshooting
Symptom Cause Corrective Action
The  ame e ect will
not start.
Mains plug is not plugged in.
Switch A is in the ‘ON’ ( I ) position, but mode
Switch B has not been pressed. (See Fig. 2)
Low water level.
Low voltage connector not connected properly.
(See Fig. 8)
Check plug is connected to wall socket correctly.
Press Switch B once for  ame e ect. (See Fig. 2)
Check the water tank is full and there is water in
the sump.
Check that the connector is inserted correctly.
(See Fig. 8)
The  ame e ect is too
low.
Flame e ect thumb wheel is set too low.
(See Fig. 2)
The water in the sump may be too high due to
the drawer being opened and closed a number
of times, water tank removed a number of
times, or the  re has been moved.
Metal Disc at the base of Sump might be dirty
(See Fig. 13)
Increase level of  ame by turning thumb wheel
D clockwise slowly. (See Fig. 2)
If water level in the sump is more than 40mm,
the sump should be removed and emptied in
the sink.
Clean Metal Disc with soft brush supplied. (See
Fig. 13) See ‘Maintenance. for a step by step
procedure.
Unpleasant smell when
unit is used.
Dirty or stale water.
Using un ltered tap water.
Clean the unit as described under maintenance.
Use only  ltered tap water.
The  ame e ect has
too much smoke.
Flame e ect setting is too high. Turn the  ame e ect Thumb Wheel ‘D’ down to
minimum and slowly turn up, about ¼ a turn, at
a time. Give the  ame generator some time to
adjust before increasing. (See Fig. 2)
Main lamps are not
working and there are
no  ames or smoke.
There is no water in the tank. Follow instructions under Maintenance, ‘Filling
the water tank’.
Check the plug is connected to wall socket
correctly.
Switch A Fig. 2 is in the ‘ON’ ( I ) position.
Press switch ‘B’ Fig. 2 until you can hear one
beep only, for  ame e ect.
Condensation on the
glass
The mist setting is too high
The glass may be cold during product start-up
Reduce the mist intensity by turning the thumb
wheel ‘D’ down
Reduce the mist intensity to low and turn switch
‘C’ to high speed.
Run the product under this setting until the
glass clears then return to your preferred
setting.
Repeat this procedure should condensation
return
Troubleshooting